review article | Q7318358 |
scholarly article | Q13442814 |
P2093 | author name string | Vasantha Vijayaraghavan | |
Vinit Swami | |||
Vasanthi Swami | |||
P2860 | cites work | Biomechanical factors affecting the bone-dental implant interface | Q33565289 |
Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments | Q33852404 | ||
The long-term efficacy of currently used dental implants: a review and proposed criteria of success | Q34050076 | ||
Reintegration of mobilized titanium implants. An experimental study in rabbit tibia. | Q34435566 | ||
Bone physiology and metabolism in dental implantology: risk factors for osteoporosis and other metabolic bone diseases | Q35187648 | ||
Diagnostic parameters for monitoring peri-implant conditions. | Q36001442 | ||
Validity and clinical significance of biomechanical testing of implant/bone interface | Q36591670 | ||
Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test | Q36681725 | ||
Methods used to assess implant stability: current status. | Q36987346 | ||
Validation of implant stability: a measure of implant permanence | Q37952106 | ||
The effect of implant design on insertion torque and immediate micromotion | Q39976143 | ||
On cutting torque measurements during implant placement: a 3-year clinical prospective study. | Q40707438 | ||
Periotest to monitor osseointegration and to check the occlusion in oral implantology | Q40782623 | ||
Evaluation of bone density using cutting resistance measurements and microradiography: an in vitro study in pig ribs | Q40974794 | ||
The reverse-torque test: a clinical report. | Q41006649 | ||
Evaluation of two different resonance frequency devices to detect implant stability: a clinical trial. | Q51073446 | ||
A comparison of two methods of enhancing implant primary stability. | Q51568026 | ||
Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. | Q51825750 | ||
Electronic monitoring of dental implant osseointegration. | Q52041165 | ||
In vivo and in vitro natural frequency analysis of periodontal conditions: an innovative method. | Q52078804 | ||
Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: A histometric study in the canine mandible | Q56958796 | ||
Pulsed oscillation technique for assessing the mechanical state of the dental implant-bone interface | Q67826185 | ||
[Periotest--a new measurement process for periodontal function] | Q70947289 | ||
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw | Q71614942 | ||
Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature | Q77919206 | ||
Imaging techniques and image interpretation for dental implant treatment | Q77919217 | ||
Assessment of implant stability as a prognostic determinant | Q77919231 | ||
A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study | Q78030589 | ||
Initial torque stability of a new bone condensing dental implant. A cohort study of 140 consecutively placed implants | Q82274253 | ||
Evaluation of modal analysis techniques using physical models to detect osseointegration of implants in transfemoral amputees | Q83268829 | ||
P433 | issue | 2 | |
P407 | language of work or name | English | Q1860 |
P304 | page(s) | 124-130 | |
P577 | publication date | 2016-04-01 | |
P1433 | published in | The journal of Indian Prosthodontic Society | Q26853802 |
P1476 | title | Current trends to measure implant stability. | |
P478 | volume | 16 |
Q58560863 | A Comparison between the Implant Stability Quotient and the Fractal Dimension of Alveolar Bone at the Implant Site |
Q90346532 | A review on the latest advancements in the non-invasive evaluation/monitoring of dental and trans-femoral implants |
Q55514446 | A study on the use of the Osstell apparatus to evaluate pedicle screw stability: An in-vitro study using micro-CT. |
Q90246463 | Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives |
Q61808742 | Comparative investigation of primary stability of four different dental implants in low-density bone model |
Q89768061 | Dental implant primary stability in different regions of the Jawbone: CBCT-based 3D finite element analysis |
Q58102009 | Development of a quantitative preclinical screening model for implant osseointegration in rat tail vertebra |
Q49693533 | Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures |
Q41365610 | Implant Stability of Biological Hydroxyapatites Used in Dentistry |
Q90447653 | Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study |
Q41251094 | Predictability of bone density at posterior mandibular implant sites using cone-beam computed tomography intensity values. |
Q38662521 | Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study |
Q88466053 | Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading |