Mechanical stability analysis of carrageenan-based polymer gel for magnetic resonance imaging liver phantom with lesion particles

scientific article

Mechanical stability analysis of carrageenan-based polymer gel for magnetic resonance imaging liver phantom with lesion particles is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1117/1.JMI.1.3.035502
P932PMC publication ID4478721
P698PubMed publication ID26158073

P2093author name stringMasoom Haider
Hani Naguib
Eunji In
P2860cites workPolymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphereQ30668546
Composition of MRI phantom equivalent to human tissuesQ31016788
An MRI tissue equivalent lesion phantom using a novel polysaccharide materialQ33371475
Elastic modulus measurements of human liver and correlation with pathologyQ34131857
Techniques for liver MR imagingQ34428450
MR pulse sequences: what every radiologist wants to know but is afraid to ask.Q36426463
A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic?Q36426617
Agarose as a tissue equivalent phantom material for NMR imagingQ36472586
New polyvinyl alcohol gel material for MRI phantomsQ36483643
Use of a modified polysaccharide gel in developing a realistic breast phantom for MRI.Q36830241
NMR relaxation data of water proton in normal tissuesQ36861218
Magnetic resonance properties of ex vivo breast tissue at 1.5 T.Q36885351
An MRI phantom material for quantitative relaxometryQ45079369
The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz.Q48875204
Relaxation times in paramagnetically doped agarose gels as a function of temperature and ion concentrationQ60536738
Value of T1 and T2 relaxation times from echoplanar MR imaging in the characterization of focal hepatic lesionsQ70654036
MR imaging of RF heating using a paramagnetic doped agarose phantomQ73937750
T1, T2 relaxation and magnetization transfer in tissue at 3TQ81019992
P433issue3
P304page(s)035502
P577publication date2014-10-01
P1433published inJournal of Medical ImagingQ27725981
P1476titleMechanical stability analysis of carrageenan-based polymer gel for magnetic resonance imaging liver phantom with lesion particles
P478volume1

Reverse relations

cites work (P2860)
Q47656219Anthropomorphic liver phantom with flow for multimodal image-guided liver therapy research and training
Q99566181Dynamic Hepatocellular Carcinoma Model Within a Liver Phantom for Multimodality Imaging
Q98945590Tissue Phantoms for Biomedical Applications in Raman Spectroscopy: A Review

Search more.