Geometric feature-based multimodal image registration of contrast-enhanced cardiac CT with gated myocardial perfusion SPECT.

scientific article

Geometric feature-based multimodal image registration of contrast-enhanced cardiac CT with gated myocardial perfusion SPECT. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1118/1.3253301
P932PMC publication ID4108676
P698PubMed publication ID20095259
P5875ResearchGate publication ID41120650

P50authorC.-C. Jay KuoQ16731109
Damini DeyQ40448199
Byung-Woo HongQ42423591
Guido GermanoQ56517381
Cheng Lai Victor HuangQ89458150
Daniel S BermanQ89697826
Piotr J SlomkaQ89794201
Amit RameshQ114442180
P2093author name stringJonghye Woo
Ronald P Karlsberg
P2860cites workA review of cardiac image registration methodsQ30765920
Multimodality image registration with software: state-of-the-artQ33395380
Automated quality control for segmentation of myocardial perfusion SPECT.Q34112498
Mutual-information-based registration of medical images: a surveyQ34220574
Multi-modal volume registration by maximization of mutual informationQ34485751
Comparative use of radionuclide stress testing, coronary artery calcium scanning, and noninvasive coronary angiography for diagnostic and prognostic cardiac assessmentQ36679655
Myocardial perfusion and function: single photon emission computed tomographyQ37005490
Applications and software techniques for integrated cardiac multimodality imagingQ37038950
Cardiac CT: state of the art for the detection of coronary arterial stenosisQ37351123
An automatic approach to the analysis, quantitation and review of perfusion and function from myocardial perfusion SPECT imagesQ41599065
AUTOMATED MULTI-MODALITY REGISTRATION OF 64-SLICE CORONARY CT ANGIOGRAPHY WITH MYOCARDIAL PERFUSION SPECT.Q42423508
Adenosine myocardial perfusion single-photon emission computed tomography in women compared with men. Impact of diabetes mellitus on incremental prognostic value and effect on patient managementQ44392647
Validation of QGS and 4D-MSPECT for quantification of left ventricular volumes and ejection fraction from gated 18F-FDG PET: comparison with cardiac MRI.Q44735854
Three-dimensional fusion of coronary arteries with myocardial perfusion distributions: clinical validationQ44891183
Automatic quantification of ejection fraction from gated myocardial perfusion SPECT.Q46496807
"Motion-frozen" display and quantification of myocardial perfusionQ46697730
Automatic quantitation of regional myocardial wall motion and thickening from gated technetium-99m sestamibi myocardial perfusion single-photon emission computed tomographyQ46890886
A viscous fluid model for multimodal non-rigid image registration using mutual information.Q48171147
Three-dimensional registration of myocardial perfusion SPECT and CT coronary angiography.Q51970480
Automated image registration of gated cardiac single-photon emission computed tomography and magnetic resonance imaging.Q52002634
Cardiac image fusion from stand-alone SPECT and CT: clinical experience.Q53483888
Validation of a new cardiac image fusion software for three-dimensional integration of myocardial perfusion SPECT and stand-alone 64-slice CT angiography.Q53502656
A variational framework for integrating segmentation and registration through active contours.Q53646881
Image quality and artifacts in coronary CT angiography with dual-source CT: initial clinical experience.Q54012458
Principal warps: thin-plate splines and the decomposition of deformationsQ56624023
Registration of cardiac SPECT/CT data through weighted intensity co-occurrence priorsQ62489262
Separate acquisition rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion single-photon emission computed tomography: a clinical validation studyQ72573690
P433issue12
P407language of work or nameEnglishQ1860
P921main subjectimage registrationQ861092
P304page(s)5467-5479
P577publication date2009-12-01
P1433published inMedical PhysicsQ15764251
P1476titleGeometric feature-based multimodal image registration of contrast-enhanced cardiac CT with gated myocardial perfusion SPECT.
P478volume36

Reverse relations

cites work (P2860)
Q34065306Automatic 3D registration of dynamic stress and rest (82)Rb and flurpiridaz F 18 myocardial perfusion PET data for patient motion detection and correction
Q33594802Automatic Alignment of Myocardial Perfusion Images With Contrast-Enhanced Cardiac Computed Tomography
Q38275048Automatic Alignment of Myocardial Perfusion Images with Contrast Cardiac Tomography
Q36480156Automatic alignment of myocardial perfusion PET and 64-slice coronary CT angiography on hybrid PET/CT.
Q30688125Automatic detection of left and right ventricles from CTA enables efficient alignment of anatomy with myocardial perfusion data
Q33605288Bidirectional elastic image registration using B-spline affine transformation
Q37873383Current state of hybrid imaging: attenuation correction and fusion
Q37895953Engineered nanoparticles for biomolecular imaging
Q90319363Image synthesis-based multi-modal image registration framework by using deep fully convolutional networks
Q48265806Method comparison for cardiac image registration of coronary computed tomography angiography and 3-D echocardiography.
Q30409323Multimodal registration via mutual information incorporating geometric and spatial context
Q38167017Multimodality image fusion for diagnosing coronary artery disease

Search more.