Dosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer

scientific article

Dosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1016/J.IJROBP.2008.11.019
P932PMC publication ID2911132
P698PubMed publication ID19251095
P5875ResearchGate publication ID24145639

P2093author name stringYing Xiao
James M Galvin
Rebecca Paulus
Lech Papiez
Robert Timmerman
Walter R Bosch
Jeff Michalski
William L Straube
P2860cites workCancer statistics, 2007Q29547293
Cancer statistics, 2006Q29615133
Cancer statistics, 2005Q29617572
Cancer statistics, 2004Q29620739
The Pittsburgh Lung Screening Study (PLuSS): outcomes within 3 years of a first computed tomography scanQ30489250
Impact of revised stage classification of lung cancer on survival: a military experienceQ33667132
Medically Inoperable Lung Carcinoma: The Role of Radiation TherapyQ33862691
Accreditation and quality assurance for Radiation Therapy Oncology Group: Multicenter clinical trials using Stereotactic Body Radiation Therapy in lung cancerQ36597088
Hypofractionation in radiation therapy and its impactQ37092017
Radiation therapy for medically inoperable stage I and II non-small cell lung cancerQ38330179
Radiation therapy in the management of medically inoperable carcinoma of the lung: results and implications for future treatment strategiesQ41134625
The international system for staging lung cancerQ41717435
Beam-commissioning methodology for a three-dimensional convolution/superposition photon dose algorithmQ42662207
Generation of photon energy deposition kernels using the EGS Monte Carlo codeQ43406010
Surgical therapy for carcinoma of the lung.Q44774757
Results of radical radiation therapy in clinical stage I, technically operable non-small cell lung cancerQ46173583
Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations.Q49071975
Predicting changes in dose distribution to tumor and normal tissue when correcting for heterogeneity in radiotherapy for lung cancer.Q51071796
Modeling dose distributions from portal dose images using the convolution/superposition method.Q51649447
Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy.Q51906516
SBRT of lung tumours: Monte Carlo simulation with PENELOPE of dose distributions including respiratory motion and comparison with different treatment planning systems.Q51909363
Interinstitutional variations in planning for stereotactic body radiation therapy for lung cancer.Q51919778
Comparison of dose calculation algorithms for treatment planning in external photon beam therapy for clinical situations.Q51930127
Dose distributions in SBRT of lung tumors: Comparison between two different treatment planning algorithms and Monte-Carlo simulation including breathing motions.Q51933244
Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium.Q51984246
Comparison of RTP dose distributions in heterogeneous phantoms with the BEAM Monte Carlo simulation system.Q52052921
Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system.Q52079051
The role of curative radiotherapy in the treatment of lung cancerQ57650892
Accuracy of two heterogeneity dose calculation algorithms for IMRT in treatment plans designed using an anthropomorphic thorax phantomQ59650981
Analysis of the influence of elective nodal irradiation on postirradiation pulmonary functionQ68459243
Collapsed cone convolution of radiant energy for photon dose calculation in heterogeneous mediaQ69705697
Prognosis and survival in resected lung carcinoma based on the new international staging systemQ69835930
Local control in medically inoperable lung cancer: an analysis of its importance in outcome and factors determining the probability of tumor eradicationQ72569982
Radiation therapy alone for stage I non-small cell lung cancerQ72569985
Investigation of the convolution method for polyenergetic spectraQ72727583
Toxicity and outcome results of RTOG 9311: a phase I-II dose-escalation study using three-dimensional conformal radiotherapy in patients with inoperable non-small-cell lung carcinomaQ81312777
P433issue4
P407language of work or nameEnglishQ1860
P921main subjectlung cancerQ47912
adaptive radiation therapyQ180507
heterogeneityQ928498
P304page(s)1235-1242
P577publication date2009-03-01
P1433published inInternational Journal of Radiation Oncology Biology PhysicsQ2296252
P1476titleDosimetric evaluation of heterogeneity corrections for RTOG 0236: stereotactic body radiotherapy of inoperable stage I-II non-small-cell lung cancer
P478volume73

Reverse relations

cites work (P2860)
Q33644800A comprehensive dosimetric study on switching from a Type-B to a Type-C dose algorithm for modern lung SBRT
Q47877896A phase I/II study on stereotactic body radiotherapy with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm for lung tumors
Q35710889Adapted Prescription Dose for Monte Carlo Algorithm in Lung SBRT: Clinical Outcome on 205 Patients
Q33645619Advances in radiotherapy techniques and delivery for non-small cell lung cancer: benefits of intensity-modulated radiation therapy, proton therapy, and stereotactic body radiation therapy
Q36468246Algorithms used in heterogeneous dose calculations show systematic differences as measured with the Radiological Physics Center's anthropomorphic thorax phantom used for RTOG credentialing
Q90105657Assessment of biological dosimetric margin for stereotactic body radiation therapy
Q35150641Clinical analysis of stereotactic body radiation therapy using extracranial gamma knife for patients with mainly bulky inoperable early stage non-small cell lung carcinoma
Q38178429Clinical introduction of Monte Carlo treatment planning for lung stereotactic body radiotherapy
Q48705863Combination effects of tissue heterogeneity and geometric targeting error in stereotactic body radiotherapy for lung cancer using CyberKnife
Q37109928Comparing the clinical outcomes in stereotactic body radiotherapy for lung tumors between Ray-Tracing and Monte-Carlo algorithms
Q38187550Correlation between target volume and electron transport effects affecting heterogeneity corrections in stereotactic body radiotherapy for lung cancer
Q49989260Credentialing of radiotherapy centres in Australasia for TROG 09.02 (Chisel) a Phase III clinical trial on stereotactic ablative body radiotherapy of early stage lung cancer.
Q36661346Differences in the dose-volume metrics with heterogeneity correction status and its influence on local control in stereotactic body radiation therapy for lung cancer
Q44560526Dose calculation differences between Monte Carlo and pencil beam depend on the tumor locations and volumes for lung stereotactic body radiation therapy
Q36555610Dose correction in lung for HDR breast brachytherapy
Q40176468Dose differences in intensity-modulated radiotherapy plans calculated with pencil beam and Monte Carlo for lung SBRT.
Q52561222Dose gradient curve: A new tool for evaluating dose gradient.
Q61446980Dose prescription with spatial uncertainty for peripheral lung SBRT
Q51403225Dosimetric comparison of robotic and conventional linac-based stereotactic lung irradiation in early-stage lung cancer.
Q42150664Dosimetric comparison of three-dimensional conformal radiotherapy, intensity modulated radiotherapy, and helical tomotherapy for lung stereotactic body radiotherapy
Q36724932Dosimetric evaluation of a simple planning method for improving intensity-modulated radiotherapy for stage III lung cancer
Q89624789Dosimetric evaluation of incorporating the revised V4.0 calibration protocol for breast intraoperative radiotherapy with the INTRABEAM system
Q33837224Dosimetric evaluation of synthetic CT for magnetic resonance-only based radiotherapy planning of lung cancer
Q36010763Dosimetric verification using monte carlo calculations for tissue heterogeneity-corrected conformal treatment plans following RTOG 0813 dosimetric criteria for lung cancer stereotactic body radiotherapy
Q52609421Dosimetrical and radiobiological approach to manage the dosimetric shift in the transition of dose calculation algorithm in radiation oncology: how to improve high quality treatment and avoid unexpected outcomes?
Q37022255Effectiveness of the Monte Carlo method in stereotactic radiation therapy applied to quasi-homogenous brain tumors
Q39820035Esophageal cancer dose escalation using a simultaneous integrated boost technique
Q51286974Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer.
Q48944841Evaluation of dose prediction error and optimization convergence error in four-dimensional inverse planning of robotic stereotactic lung radiotherapy
Q40105418Evaluation of pencil beam convolution and anisotropic analytical algorithms in stereotactic lung irradiation
Q47097838Evaluation of ray tracing and Monte Carlo algorithms in dose calculation and clinical outcomes for robotic stereotactic body radiotherapy of lung cancers
Q99582898Four-year follow-up outcomes after stereotactic body radiation therapy for central early-stage non-small cell lung cancer
Q34381901GTV-based prescription in SBRT for lung lesions using advanced dose calculation algorithms
Q30493924Imaging primary lung cancers in mice to study radiation biology.
Q38272276Impact of dose calculation algorithm on radiation therapy
Q37698823Low incidence of chest wall pain with a risk-adapted lung stereotactic body radiation therapy approach using three or five fractions based on chest wall dosimetry
Q55073350Lung SBRT: dosimetric and delivery comparison of RapidArc, TomoTherapy, and IMRT.
Q33758565No clinically significant changes in pulmonary function following stereotactic body radiation therapy for early- stage peripheral non-small cell lung cancer: an analysis of RTOG 0236
Q49749018Optimizing the prescription isodose level in stereotactic volumetric-modulated arc radiotherapy of lung lesions as a potential for dose de-escalation
Q95841272Radiation-Induced Secondary Cancer Risk Assessment in Patients With Lung Cancer After Stereotactic Body Radiotherapy Using the CyberKnife M6 System With Lung-Optimized Treatment
Q92973685Risk-adapted stereotactic body radiation therapy for central and ultra-central early-stage inoperable non-small cell lung cancer
Q98771302Significant Correlation Between Overall Survival and Mean Lung Dose in Lung Stereotactic Body Radiation Therapy (SBRT)
Q47891076Small field dose measurements using plastic scintillation detector in heterogeneous media.
Q56523398Stereotactic Body Radiation Therapy for Operable Early-Stage Lung Cancer: Findings From the NRG Oncology RTOG 0618 Trial
Q35667834Stereotactic ablative radiotherapy (SABR) for lung cancer: What does the future hold?
Q34010065Stereotactic body radiation therapy for inoperable early stage lung cancer
Q60912983Stereotactic body radiation therapy for non-small cell lung cancer: A review
Q64922876Stereotactic body radiation therapy versus surgery for early stage non-small cell lung cancer: clearing a path through an evolving treatment landscape.
Q42033188Stereotactic body radiotherapy for small lung tumors in the University of Tokyo Hospital
Q38175120Stereotactic body radiotherapy: a critical review for nonradiation oncologists
Q36644220The effect of beam arrangements and the impact of non-coplanar beams on the treatment planning of stereotactic ablative radiation therapy for early stage lung cancer
Q47734152The impact of technology on the changing practice of lung SBRT.