Accuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone

scientific article

Accuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1002/JBMR.92
P932PMC publication ID3118020
P698PubMed publication ID20499379
P5875ResearchGate publication ID44627378

P50authorXiaowei Sherry LiuQ42889447
P2093author name stringPaul Sajda
X Edward Guo
Felix W Wehrli
Chamith S Rajapakse
Jeremy Magland
Kiranjit K Sekhon
Mark F Adam
Michael J Wald
X Henry Zhang
P2860cites workDirect three-dimensional morphometric analysis of human cancellous bone: microstructural data from spine, femur, iliac crest, and calcaneus.Q30579244
Quantification of trabecular bone structure using magnetic resonance imaging at 3 Tesla--calibration studies using microcomputed tomography as a standard of referenceQ33728546
Computational biomechanics of the distal tibia from high-resolution MR and micro-CT imagesQ34079635
Alterations of cortical and trabecular architecture are associated with fractures in postmenopausal women, partially independent of decreased BMD measured by DXA: the OFELY study.Q34593182
Bone density, geometry, microstructure, and stiffness: Relationships between peripheral and central skeletal sites assessed by DXA, HR-pQCT, and cQCT in premenopausal womenQ35084222
High-resolution peripheral quantitative computed tomography can assess microstructural and mechanical properties of human distal tibial boneQ35087862
Quantification of the roles of trabecular microarchitecture and trabecular type in determining the elastic modulus of human trabecular boneQ35575608
Trabecular bone structure of the calcaneus: preliminary in vivo MR imaging assessment in men with osteoporosisQ73218012
Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous boneQ73531457
Quantification of Bone Microarchitecture with the Structure Model IndexQ73663325
Cancellous bone volume and structure in the forearm: noninvasive assessment with MR microimaging and image processingQ74147605
Changes in calcaneal trabecular bone structure assessed with high-resolution MR imaging in patients with kidney transplantationQ77797040
Structural determinants of vertebral fracture riskQ80752742
Finite element analysis based on in vivo HR-pQCT images of the distal radius is associated with wrist fracture in postmenopausal womenQ81588606
Structural and functional assessment of trabecular and cortical bone by micro magnetic resonance imagingQ36721152
Correlation of trabecular bone structure with age, bone mineral density, and osteoporotic status: in vivo studies in the distal radius using high resolution magnetic resonance imagingQ36873850
Trabecular structure quantified with the MRI-based virtual bone biopsy in postmenopausal women contributes to vertebral deformity burden independent of areal vertebral BMD.Q37145984
In vivo magnetic resonance detects rapid remodeling changes in the topology of the trabecular bone network after menopause and the protective effect of estradiolQ37172782
In vivo microMRI-based finite element and morphological analyses of tibial trabecular bone in eugonadal and hypogonadal men before and after testosterone treatmentQ37194918
Spin-echo micro-MRI of trabecular bone using improved 3D fast large-angle spin-echo (FLASE)Q37317809
Implications of noise and resolution on mechanical properties of trabecular bone estimated by image-based finite-element analysisQ37356264
Trabecular bone structure analysis in the limited spatial resolution regime of in vivo MRI.Q37409512
Bone microarchitecture and stiffness in premenopausal women with idiopathic osteoporosis.Q37417497
Digital topological analysis of in vivo magnetic resonance microimages of trabecular bone reveals structural implications of osteoporosisQ39576296
The role of an effective isotropic tissue modulus in the elastic properties of cancellous boneQ40806460
Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular boneQ41056339
Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference.Q43680921
High-resolution MRI and micro-FE for the evaluation of changes in bone mechanical properties during longitudinal clinical trials: application to calcaneal bone in postmenopausal women after one year of idoxifene treatmentQ43879125
In vivo high resolution MRI of the calcaneus: differences in trabecular structure in osteoporosis patientsQ44006276
Magnetic resonance imaging of trabecular bone structure in the distal radius: relationship with X-ray tomographic microscopy and biomechanicsQ44178248
Deterioration of trabecular architecture in hypogonadal men.Q44392836
In vivo application of 3D-line skeleton graph analysis (LSGA) technique with high-resolution magnetic resonance imaging of trabecular bone structureQ44800159
In vivo relationship between marrow T2* and trabecular bone density determined with a chemical shift-selective asymmetric spin-echo sequenceQ46001428
Feasibility of in vivo structural analysis of high-resolution magnetic resonance images of the proximal femur.Q46007464
Heterogeneity of trabecular bone structure in the calcaneus using magnetic resonance imaging.Q46025472
In vivo assessment of architecture and micro-finite element analysis derived indices of mechanical properties of trabecular bone in the radiusQ46076002
Fuzzy logic structure analysis of trabecular bone of the calcaneus to estimate proximal femur fracture load and discriminate subjects with and without vertebral fractures using high-resolution magnetic resonance imaging at 1.5 T and 3 T.Q46106448
Direct measures of trabecular bone architecture from MR imagesQ46227931
Effect of testosterone replacement on trabecular architecture in hypogonadal men.Q46701609
Assessment of trabecular bone structure comparing magnetic resonance imaging at 3 Tesla with high-resolution peripheral quantitative computed tomography ex vivo and in vivoQ46718645
In vivo determination of bone structure in postmenopausal women: a comparison of HR-pQCT and high-field MR imagingQ46858557
New model-independent measures of trabecular bone structure applied to in vivo high-resolution MR imagesQ46881934
Measurement of trabecular bone thickness in the limited resolution regime of in vivo MRI by fuzzy distance transformQ47269053
A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stressQ48556188
Assessment of cancellous bone mechanical properties from micro-FE models based on micro-CT, pQCT and MR imagesQ48583339
Effects of thresholding techniques on microCT-based finite element models of trabecular bone.Q50950578
A novel local thresholding algorithm for trabecular bone volume fraction mapping in the limited spatial resolution regime of in vivo MRI.Q51958223
Does the trabecular bone structure depicted by high-resolution MRI of the calcaneus reflect the true bone structure?Q52066336
In vivo micro-imaging using alternating navigator echoes with applications to cancellous bone structural analysis.Q52214556
Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture.Q52290577
Three-dimensional nuclear magnetic resonance microimaging of trabecular bone.Q52327529
Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions.Q52400421
Wolff's law of trabecular architecture at remodeling equilibrium.Q52647256
Advances of 3T MR imaging in visualizing trabecular bone structure of the calcaneus are partially SNR-independent: analysis using simulated noise in relation to micro-CT, 1.5T MRI, and biomechanical strength.Q53379846
Contribution of In Vivo Structural Measurements and Load/Strength Ratios to the Determination of Forearm Fracture Risk in Postmenopausal WomenQ53528272
The direct examination of three-dimensional bone architecture in vitro by computed tomographyQ69606673
P433issue9
P407language of work or nameEnglishQ1860
P921main subjectmicrostructureQ1498213
P304page(s)2039-2050
P577publication date2010-09-01
P1433published inJournal of Bone and Mineral ResearchQ15750941
P1476titleAccuracy of high-resolution in vivo micro magnetic resonance imaging for measurements of microstructural and mechanical properties of human distal tibial bone
P478volume25

Reverse relations

cites work (P2860)
Q35146437Abnormal microarchitecture and reduced stiffness at the radius and tibia in postmenopausal women with fractures.
Q49571933Accuracy of MRI-based finite element assessment of distal tibia compared to mechanical testing
Q36553060Better skeletal microstructure confers greater mechanical advantages in Chinese-American women versus white women
Q35084222Bone density, geometry, microstructure, and stiffness: Relationships between peripheral and central skeletal sites assessed by DXA, HR-pQCT, and cQCT in premenopausal women
Q38759091Clinical Evaluation of Bone Strength and Fracture Risk
Q34268022Collagen mutation causes changes of the microdamage morphology in bone of an OI mouse model
Q92738550Comparison of methods for assigning the material properties of the distraction callus in computational models
Q36984128Deterioration of trabecular plate-rod and cortical microarchitecture and reduced bone stiffness at distal radius and tibia in postmenopausal women with vertebral fractures
Q35229984Determinants of the mechanical behavior of human lumbar vertebrae after simulated mild fracture
Q36573777Differences in bone microarchitecture between postmenopausal Chinese-American and white women
Q38797594Emerging role of high-resolution imaging in the detection of renal osteodystrophy.
Q36944938Fast trabecular bone strength predictions of HR-pQCT and individual trabeculae segmentation-based plate and rod finite element model discriminate postmenopausal vertebral fractures
Q37732469Feasibility of three-dimensional MRI of proximal femur microarchitecture at 3 tesla using 26 receive elements without and with parallel imaging.
Q34681094Finite element analysis applied to 3-T MR imaging of proximal femur microarchitecture: lower bone strength in patients with fragility fractures compared with control subjects.
Q34904469Helmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T.
Q52980198Impaired Bone Microarchitecture Improves After One Year On Gluten-Free Diet: A Prospective Longitudinal HRpQCT Study in Women With Celiac Disease.
Q38685492Impaired bone strength estimates at the distal tibia and its determinants in adolescents with anorexia nervosa.
Q41481948In Vivo Gait Analysis During Bone Transport.
Q37044659In vivo estimation of bone stiffness at the distal femur and proximal tibia using ultra-high-field 7-Tesla magnetic resonance imaging and micro-finite element analysis
Q35091895Individual trabeculae segmentation (ITS)-based morphological analysis of high-resolution peripheral quantitative computed tomography images detects abnormal trabecular plate and rod microarchitecture in premenopausal women with idiopathic osteoporos
Q38761009MRI assessment of bone structure and microarchitecture.
Q92571117MRI-based assessment of proximal femur strength compared to mechanical testing
Q35773561Micro-MR imaging-based computational biomechanics demonstrates reduction in cortical and trabecular bone strength after renal transplantation
Q37036884Micro-finite element analysis applied to high-resolution MRI reveals improved bone mechanical competence in the distal femur of female pre-professional dancers
Q92509785Next-generation imaging of the skeletal system and its blood supply
Q35703263Noninvasive imaging of bone microarchitecture.
Q35196467Performance of the MRI-based virtual bone biopsy in the distal radius: serial reproducibility and reliability of structural and mechanical parameters in women representative of osteoporosis study populations.
Q36031010Predicting trabecular bone elastic properties from measures of bone volume fraction and fabric on the basis of micromagnetic resonance images
Q30683446Rapid ex vivo imaging of PAIII prostate to bone tumor with SWIFT-MRI
Q36473294Research perspectives: The 2013 AAOS/ORS research symposium on Bone Quality and Fracture Prevention.
Q35229835Role of trabecular microarchitecture and its heterogeneity parameters in the mechanical behavior of ex vivo human L3 vertebrae
Q45810352Spatial-temporal mapping of bone structural and elastic properties in a sheep model following osteotomy
Q38666440The Efficacy of Low-intensity Vibration to Improve Bone Health in Patients with End-stage Renal Disease Is Highly Dependent on Compliance and Muscle Response
Q30455916The effect of voxel size on high-resolution peripheral computed tomography measurements of trabecular and cortical bone microstructure
Q38001598Trabecular architecture and vertebral fragility in osteoporosis
Q53645551[High resolution peripheral quantitative computed tomography for the assessment of morphological and mechanical bone parameters].

Search more.