The influence of kinematic conditions and design on the wear of patella-femoral replacements

scientific article

The influence of kinematic conditions and design on the wear of patella-femoral replacements is …
instance of (P31):
scholarly articleQ13442814

External links are
P5530Altmetric DOI10.1177/0954411913518910
P6179Dimensions Publication ID1027487853
P356DOI10.1177/0954411913518910
P8608Fatcat IDrelease_vtdu2xlbo5dwtlz42rockg7u2y
P953full work available at URLhttp://eprints.whiterose.ac.uk/77479/
https://doi.org/10.1177/0954411913518910
P932PMC publication ID4361355
P698PubMed publication ID24477888
P5875ResearchGate publication ID259985716
P1154Scopus EID2-s2.0-84896794908

P50authorRaman MaitiQ63284574
John FisherQ18705161
Louise JenningsQ53769847
P2093author name stringLiam Rowley
P2860cites workA new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacementQ56991950
The wear of fixed and mobile bearing unicompartmental knee replacementsQ59902945
A novel method for the prediction of functional biological activity of polyethylene wear debrisQ73945685
Wear pattern of retrieved patellar implantsQ78473110
The effect of femoral component malrotation on patellar biomechanicsQ82663332
Patellar button wear patterns in well-functioning total knee arthroplasty retrievalsQ83339088
Biomechanical consequences of patellar component medialization in total knee arthroplastyQ84322017
Biological activity of polyethylene wear debris produced in the patellofemoral jointQ84428483
Knee arthroplasty in Denmark, Norway and Sweden. A pilot study from the Nordic Arthroplasty Register AssociationQ33795822
Early outcomes of patella resurfacing in total knee arthroplastyQ33795851
Biological reactions to wear debris in total joint replacementQ33863354
International survey of primary and revision total knee replacementQ34170780
Biomechanics of patellofemoral joint prosthesesQ36182796
Quantification of the effect of cross-shear on the wear of conventional and highly cross-linked UHMWPEQ41862125
2009 Knee Society Presidential Guest Lecture: Polyethylene wear in total kneesQ42114868
The influence of malrotation and femoral component material on patellofemoral wear during gaitQ44151967
Assessment of the damage in retrieved patellar componentsQ44530518
The size and shape of particulate polyethylene wear debris in total joint replacementsQ47317716
The effect of an augmentation patella prosthesis versus patelloplasty on revision patellar kinematics and quadriceps tendon force: an ex vivo studyQ47659705
A highly crosslinked UHMWPE for CR and PS total knee arthroplastiesQ47671767
In vitro simulation and quantification of wear within the patellofemoral joint replacement.Q47777028
Investigation on wear of knee prostheses under fixed kinematic conditionsQ47986671
Malrotation causing patellofemoral complications after total knee arthroplasty.Q49088258
Wear and deformation of patellar components in total knee arthroplasty.Q50799358
The influence of femoral condylar lift-off on the wear of artificial knee joints.Q50991424
Comparison of conventional and highly crosslinked UHMWPE patellae evaluated by a new in vitro patellofemoral joint simulator.Q51219112
Clinical and biomechanical assessment of patella resurfacing in total knee arthroplasty.Q51253395
The influence of design, materials and kinematics on the in vitro wear of total knee replacements.Q51567391
Explicit finite element modeling of total knee replacement mechanics.Q51567403
Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns.Q51584073
Simultaneous in vitro measurement of patellofemoral kinematics and forces.Q51624771
Long-term results of patellofemoral arthroplasty. A report of 56 arthroplasties with 17 years of follow-up.Q51833717
Three-dimensional kinematics of the human knee during walkingQ52423036
A mathematical model of the patellofemoral joint.Q52653035
Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses.Q52849425
P433issue2
P304page(s)175-181
P577publication date2014-01-29
P1433published inProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in MedicineQ7247187
P859sponsorApplication of a High Field and High Resolution MRI to Tribological Studies of Articular CartilageQ63378489
P1476titleThe influence of kinematic conditions and design on the wear of patella-femoral replacements
P478volume228

Reverse relations

Q33865982The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacementscites workP2860

Search more.