A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements

scientific article

A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1136/BJO.84.4.403
P932PMC publication ID1723420
P698PubMed publication ID10729299

P2093author name stringDiamond JP
Shuttleworth GN
Khong CH
P2860cites workOptic disc cupping as clinically estimated from photographsQ69454572
Optic nerve damage in human glaucoma. III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathyQ70269954
The mode of progressive disc cupping in ocular hypertension and glaucomaQ71153898
Interobserver and intraobserver variability in the detection of glaucomatous progression of the optic discQ71839965
Ophthalmoscopic evaluation of the optic nerve headQ33534643
The Bristol Shared Care Glaucoma Study: reliability of community optometric and hospital eye service test measuresQ33643032
Clinical evaluation of the optic nerve in glaucomaQ34164155
Comparison of photographic techniques and films used in stereophotogrammetry of the optic diskQ36542903
Agreement between clinicians and a confocal scanning laser ophthalmoscope in estimating cup/disk ratiosQ36699425
Comparative reproducibility of the digital photogrammetric procedure utilizing three methods of stereophotographyQ36764824
Relative optic cup depth assessments using three stereo photograph viewing methods.Q36818389
Variability of expert observers in evaluating the optic discQ40539134
Optic disc parameters and onset of glaucomatous field loss. I. Methods and progressive changes in disc morphologyQ41722858
Quantitation of optic disc cuppingQ44042474
Randomized controlled clinical trial. National Eye Institute workshop for ophthalmologists. Standardizing diagnostic proceduresQ44610046
Methodologic differences and measurement of cup-disc ratio: an epidemiologic assessmentQ46863435
Agreement between clinicians and an image analyzer in estimating cup-to-disc ratios.Q50535884
Expert agreement in evaluating the optic disc for glaucomaQ52861434
Agreement among optometrists, ophthalmologists, and residents in evaluating the optic disc for glaucoma.Q52881421
Progression of disc and field damage in early glaucoma.Q54054059
Intraobserver and Interobserver Agreement in Measurement of Optic Disc CharacteristicsQ58760553
Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field lossQ68183185
P433issue4
P407language of work or nameEnglishQ1860
P304page(s)403-407
P577publication date2000-04-01
P1433published inBritish Journal of OphthalmologyQ13443571
P1476titleA new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements
P478volume84

Reverse relations

cites work (P2860)
Q485959003D vs 2D qualitative and semiquantitative evaluation of the glaucomatous optic disc atrophy using computer-assisted stereophotography
Q39639929A comparison of cup-to-disc ratio evaluation in normal subjects using stereo biomicroscopy and digital imaging of the optic nerve head.
Q45112530A comparison of cup-to-disc ratio measurement in normal subjects using optical coherence tomography image analysis of the optic nerve head and stereo fundus biomicroscopy
Q35318007A comparison of stereoscopic and monoscopic evaluation of optic disc topography using a digital optic disc stereo camera
Q48089839Agreement among ophthalmologists in marking the optic disc and optic cup in fundus images
Q35589447Agreement in assessing optic discs with a digital stereoscopic optic disc camera (Discam) and Heidelberg retina tomograph
Q34089853Automated segmentation of the cup and rim from spectral domain OCT of the optic nerve head.
Q30976284Comparison of optic nerve head assessment with a digital stereoscopic camera (discam), scanning laser ophthalmoscopy, and stereophotography
Q39720872Digital imaging of the optic nerve head: monoscopic and stereoscopic analysis.
Q33223153Digitizing stereoscopic optic nerve head photographs for storage and viewing using a personal computer
Q36172329Effect of pupillary dilatation on glaucoma assessments using optical coherence tomography
Q42606513Initial management of ocular hypertension and primary open-angle glaucoma: an evaluation of the royal college of ophthalmologists' guidelines
Q34471403Test-retest variability in structural parameters measured with glaucoma imaging devices
Q52936303The Ocular Hypertension Treatment Study: reproducibility of cup/disk ratio measurements over time at an optic disc reading center.
Q34772761The reliability of clinical methods in ophthalmology
Q34702045Utility of digital stereo images for optic disc evaluation
Q40103500Validity of a new optic disc grading software for use in clinical and epidemiological research
Q53848140[Early optic disc changes in open-angle glaucoma].
Q53514482[Time-multiplexing stereophotography: 2D and 3D qualitative and semiquantitative evaluation of glaucomatous optic disc atrophy]

Search more.