Stent application for the treatment of cerebral aneurysms

scientific article published on 31 August 2011

Stent application for the treatment of cerebral aneurysms is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.5469/NEUROINT.2011.6.2.53
P932PMC publication ID3214816
P698PubMed publication ID22125751
P5875ResearchGate publication ID51838632

P2093author name stringDong Ik Kim
Dong Joon Kim
Byung Moon Kim
P2860cites workCombined endovascular treatment of dissecting vertebral artery aneurysms by using stents and coilsQ34173036
Stent-assisted coil embolization of wide-necked intracranial aneurysms using a semi-deployment technique: angiographic and clinical outcomes in 31 consecutive patientsQ35752434
Balloon-in-stent technique for the constructive endovascular treatment of "ultra-wide necked" circumferential aneurysmsQ36332406
Saccular intracranial aneurysms: endovascular treatment - devices, techniques and strategies, management of complications, resultsQ36578805
Endovascular coil occlusion of intracranial aneurysms assisted by a novel self-expandable nitinol microstent (neuroform).Q36622180
Stent-assisted embolization of wide-neck anterior communicating artery aneurysms: review of 21 consecutive casesQ37491893
Wide-necked intracranial aneurysms: treatment with stent-assisted coil embolization during acute (<72 hours) subarachnoid hemorrhage--experience in 61 consecutive patientsQ37587619
Endovascular treatment of wide-neck middle cerebral artery aneurysms with stents: a review of 16 casesQ37665756
Mid-term results of endovascular coiling of wide-necked aneurysms using double stents in a Y configurationQ37851332
Delivery technique plays an important role in determining vessel wall apposition of the Enterprise self-expanding intracranial stentQ39016584
Treatment of a vertebral dissecting aneurysm with stents and coils: technical case reportQ39472795
Partially clipped intracranial aneurysm obliterated with combined stent and coil implantationQ39602468
Horizontal stent-assisted coil embolisation of wide-necked intracranial aneurysms with the Enterprise stent--a case series with early angiographic follow-upQ39877250
Stent-Assisted Coiling of Complex Middle Cerebral Artery Aneurysms: Initial and Midterm ResultsQ39955757
Intravascular stent and endovascular coil placement for a ruptured fusiform aneurysm of the basilar artery. Case report and review of the literatureQ41652188
"Waffle cone"technique for intra/extra-aneurysmal stent placement for the treatment of complex and wide-necked bifurcation aneurysmQ41970741
Semi-jailing technique for coil embolization of complex, wide-necked intracranial aneurysmsQ43236492
Treatment of a wide-necked aneurysm of the anterior cerebral artery using two Enterprise stents in "Y"-configuration stenting technique and coil embolization: a technical noteQ43257900
Early fatal hemorrhage after endovascular cerebral aneurysm treatment with a flow diverter (SILK-Stent): do we need to rethink our concepts?Q46113714
Endovascular treatment of wide-necked aneurysms by using two microcatheters: techniques and outcomes in 25 patientsQ46426064
Stent reconstruction of wide-necked aneurysms across the circle of WillisQ46842697
Curative reconstruction of a giant midbasilar trunk aneurysm with the pipeline embolization deviceQ47197136
Reconstructive endovascular treatment of ruptured blood blister-like aneurysms of the internal carotid artery.Q47204930
Stent-jack technique in stent-assisted coiling of wide-neck aneurysmsQ47449623
Definitive reconstruction of circumferential, fusiform intracranial aneurysms with the pipeline embolization deviceQ47612699
Hemorrhagic complications related to the stent-remodeled coil embolization of intracranial aneurysms.Q48160746
Stent-assisted coil placement in a wide-necked persistent trigeminal artery aneurysm with jailing of the trigeminal artery: a case report.Q48657539
Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up.Q50907989
Use of self-expanding stents in distal small cerebral vessels.Q51051057
Neuroform in-stent stenosis: incidence, natural history, and treatment strategies.Q51167937
Y-configured dual intracranial stent-assisted coil embolization for the treatment of wide-necked basilar tip aneurysms.Q51490564
Y-stent-assisted coil embolization for the management of unruptured cerebral aneurysms: report of six cases.Q51625436
Preliminary experience using the Neuroform stent for the treatment of cerebral aneurysms.Q51729821
The Neuroform stent, the first microcatheter-delivered stent for use in the intracranial circulation.Q51729825
Coil embolization of unruptured middle cerebral artery aneurysms.Q53162928
Endovascular coil embolization of aneurysms with a branch incorporated into the sac.Q53497094
Clinical and angiographic follow-up of stent-only therapy for acute intracranial vertebrobasilar dissecting aneurysms.Q53512358
Stent-assisted coil embolization followed by a stent-within-a-stent technique for ruptured dissecting aneurysms of the intracranial vertebrobasilar artery. Clinical article.Q53512842
Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysmsQ57218964
Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatmentQ82430760
Linear stent-assisted coiling: another way to treat very wide-necked intracranial aneurysmsQ82510923
X-configuration stent-assisted coilingQ83385485
Neuroform stent-assisted embolization of incidental anterior communicating artery aneurysms: long-term clinical and angiographic follow-upQ83395840
A comparison of functional and physical properties of self-expanding intracranial stents [Neuroform3, Wingspan, Solitaire, Leo+, Enterprise]Q83908396
Endovascular treatment of cerebral aneurysms with the use of stents in small cerebral vesselsQ84713107
Waffle-cone technique with Solitaire™ AB Remodeling Device: endovascular treatment of highly selected complex cerebral aneurysmsQ84990247
Stent assisted coiling of the ruptured wide necked intracranial aneurysmQ85078195
P275copyright licenseCreative Commons Attribution-NonCommercial 3.0 UnportedQ18810331
P6216copyright statuscopyrightedQ50423863
P433issue2
P304page(s)53-70
P577publication date2011-08-31
P1433published inNeurointerventionQ26842135
P1476titleStent application for the treatment of cerebral aneurysms
P478volume6

Reverse relations

cites work (P2860)
Q64228985A Newly-Developed Flow Diverter (FloWise) for Internal Carotid Artery Aneurysm: Results of a Pilot Clinical Study
Q47378832A new low-profile visualized intraluminal support (LVIS) device, LVIS Blue: laboratory comparison between old and new LVIS.
Q91933210Accuracy of Length of Virtual Stents in Treatment of Intracranial Wide-Necked Aneurysms
Q50860577Association of Different Stenting Procedures with Symptomatic Thromboembolic Complications in Stent-Assisted Coiling of Ruptured Wide-Necked Intracranial Aneurysms.
Q89832363Basilar Apex Aneurysm: Case Series, Systematic Review, and Meta-analysis
Q36313973Bench-top Comparison of Physical Properties of 4 Commercially-Available Self-Expanding Intracranial Stents
Q36225517Clinical and Angiographic Outcomes of Aneurysms Treated with Two Self-expanding Stent-assisted Coiling Systems: A Comparison of Solitaire AB and Enterprise VRD Stents
Q40527858Combination of Multicatheter Plus Stent or Balloon for Treatment of Complex Aneurysms.
Q59181040Comparative Cost Analysis for the Surgical and Endovascular Treatment of Ruptured Intracranial Aneurysms in Taiwan: A Nationwide Population-Based Cohort Study
Q41062148Comparison Between Balloon-Assisted and Stent-Assisted Technique for Treatment of Unruptured Internal Carotid Artery Aneurysms
Q102049990Comparison of clinical outcomes after stent-assisted coiling with three types of self-expanding laser-cut stents in patients with wide-necked intracranial aneurysms
Q88416982Does stent type impact coil embolization outcomes in extended follow-up of small-sized aneurysms (< 10 mm)?
Q35950677Easy Advancement of a Large-Profile Microcatheter (Excelsior XT27™) by Parallel Use of Two Microguidewires For Stent Delivery
Q37168565Initial experience with the new double-lumen scepter balloon catheter for treatment of wide-necked aneurysms
Q51534918LVIS Jr 'shelf' technique: an alternative to Y stent-assisted aneurysm coiling.
Q41271876Misaligned pCONus Device: Case Report of a Unique Complication
Q36661150Pipeline Embolization Device for Large/Giant or Fusiform Aneurysms: An Initial Multi-Center Experience in Korea
Q37720602Semi-Jailing Technique Using a Neuroform3 Stent for Coiling of Wide-Necked Intracranial Aneurysms
Q91756659Stent-Assisted Coil Embolization of MCA Bifurcation Aneurysms at a Hypoplastic M1 Branch by Use of Hook Technique
Q33630178Treatment of rabbit carotid aneurysms by hybrid stents (microporous thin polyurethane-covered stents): preservation of side-branches
Q47136319Un-re-sheath-able Misaligned pCONus Device: Case Report of a Unique Complication
Q92576556Visualization of stent apposition after stent-assisted coiling of intracranial aneurysms using high resolution 3D fusion images acquired by C-arm CT

Search more.