scholarly article | Q13442814 |
P356 | DOI | 10.4047/JAP.2015.7.2.115 |
P8608 | Fatcat ID | release_lumlzvsctzdv5cndmze6q53t3e |
P932 | PMC publication ID | 4414941 |
P698 | PubMed publication ID | 25932309 |
P5875 | ResearchGate publication ID | 275663930 |
P50 | author | Sun-Young Lee | Q87226018 |
Sung-Jun Kim | Q87226020 | ||
Hyun-Wook An | Q87226023 | ||
Hyun-Seung Kim | Q87226025 | ||
Dong-Guk Ha | Q87226027 | ||
Kyung-Ho Ryo | Q87226029 | ||
Kwang-Bum Park | Q87226033 | ||
P2093 | author name string | Sun-Young Lee | |
Sung-Jun Kim | |||
Hyun-Seung Kim | |||
Kwang-Bum Park | |||
Hyun-Wook An | |||
Dong-Guk Ha | |||
Kyung-Ho Ryo | |||
P2860 | cites work | Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeys | Q34413955 |
Effect of micrometer-scale roughness of the surface of Ti6Al4V pedicle screws in vitro and in vivo | Q37145446 | ||
The effect of thread pattern upon implant osseointegration | Q37587371 | ||
Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study | Q39878245 | ||
The effects of superficial roughness and design on the primary stability of dental implants | Q39899889 | ||
Stress fatigue: basic principles and prosthodontic implications | Q40422715 | ||
Implant stability in posterior maxilla: bone-condensing versus bone-drilling: a clinical study | Q43456527 | ||
Bone particles and the undersized surgical technique | Q46296953 | ||
The excessive loss of Branemark fixtures in type IV bone: a 5-year analysis | Q46958012 | ||
Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis | Q47237370 | ||
Optimal design of thread height and width on an immediately loaded cylinder implant: a finite element analysis | Q47425542 | ||
Impact of implant design on primary stability of orthodontic mini-implants | Q47964832 | ||
Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets | Q84405860 | ||
Effects of the taper shape, dual-thread, and length on the mechanical properties of mini-implants | Q84462809 | ||
Effect of surgical techniques on primary implant stability and peri-implant bone. | Q50860466 | ||
Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. | Q51033577 | ||
Primary stability of a conical implant and a hybrid, cylindric screw-type implant in vitro. | Q51136626 | ||
Significance of primary stability for osseointegration of dental implants. | Q51211949 | ||
Recommended placement torque when tightening an orthodontic mini-implant. | Q51280828 | ||
Clinical outcome of Brånemark System implants of various diameters: a retrospective study. | Q52030493 | ||
Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effects of blasting material and surface topography | Q71881038 | ||
The relationship of Periotest values, biomaterial, and torque to failure in adult baboons | Q72142261 | ||
Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25- and 75-microns-sized particles of Al2O3 | Q73037168 | ||
A prospective multicenter clinical study of the Osseotite implant: four-year interim report | Q73809538 | ||
Evaluation of design parameters of osseointegrated dental implants using finite element analysis | Q74318434 | ||
Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulation | Q74544270 | ||
Mobility assessment with the Periotest system in relation to histologic findings of oral implants | Q74691289 | ||
Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study | Q82491870 | ||
Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: is there a relationship? An in vitro study | Q82503411 | ||
Immediate rehabilitation of the edentulous mandible with screw type implants: results after up to 10 years of clinical function | Q82548531 | ||
Comparison of crestal bone loss and implant stability among the implants placed with conventional procedure and using osteotome technique: a clinical study | Q82808707 | ||
Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density bone | Q83409274 | ||
P275 | copyright license | Creative Commons Attribution-NonCommercial 3.0 Unported | Q18810331 |
P6216 | copyright status | copyrighted | Q50423863 |
P433 | issue | 2 | |
P407 | language of work or name | English | Q1860 |
P304 | page(s) | 115-121 | |
P577 | publication date | 2015-04-23 | |
P1433 | published in | The journal of advanced prosthodontics | Q26842721 |
P1476 | title | The effect of the thread depth on the mechanical properties of the dental implant | |
P478 | volume | 7 |
Q54940704 | Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design. |
Q90447653 | Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study |
Q42085212 | Inlay osteotome sinus floor elevation with concentrated growth factor application and simultaneous short implant placement in severely atrophic maxilla |
Q92257996 | Primary Stability Optimization by Using Fixtures with Different Thread Depth According To Bone Density: A Clinical Prospective Study on Early Loaded Implants |
Q92554994 | [Expert consensus on biomechanical research of dental implant] |