The effect of the thread depth on the mechanical properties of the dental implant.

scientific article published on 23 April 2015

The effect of the thread depth on the mechanical properties of the dental implant. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.4047/JAP.2015.7.2.115
P8608Fatcat IDrelease_lumlzvsctzdv5cndmze6q53t3e
P932PMC publication ID4414941
P698PubMed publication ID25932309
P5875ResearchGate publication ID275663930

P50authorSun-Young LeeQ87226018
Sung-Jun KimQ87226020
Hyun-Wook AnQ87226023
Hyun-Seung KimQ87226025
Dong-Guk HaQ87226027
Kyung-Ho RyoQ87226029
Kwang-Bum ParkQ87226033
P2093author name stringSun-Young Lee
Sung-Jun Kim
Hyun-Seung Kim
Kwang-Bum Park
Hyun-Wook An
Dong-Guk Ha
Kyung-Ho Ryo
P2860cites workLoss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeysQ34413955
Effect of micrometer-scale roughness of the surface of Ti6Al4V pedicle screws in vitro and in vivoQ37145446
The effect of thread pattern upon implant osseointegrationQ37587371
Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory studyQ39878245
The effects of superficial roughness and design on the primary stability of dental implantsQ39899889
Stress fatigue: basic principles and prosthodontic implicationsQ40422715
Implant stability in posterior maxilla: bone-condensing versus bone-drilling: a clinical studyQ43456527
Bone particles and the undersized surgical techniqueQ46296953
The excessive loss of Branemark fixtures in type IV bone: a 5-year analysisQ46958012
Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysisQ47237370
Optimal design of thread height and width on an immediately loaded cylinder implant: a finite element analysisQ47425542
Impact of implant design on primary stability of orthodontic mini-implantsQ47964832
Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant socketsQ84405860
Effects of the taper shape, dual-thread, and length on the mechanical properties of mini-implantsQ84462809
Effect of surgical techniques on primary implant stability and peri-implant bone.Q50860466
Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.Q51033577
Primary stability of a conical implant and a hybrid, cylindric screw-type implant in vitro.Q51136626
Significance of primary stability for osseointegration of dental implants.Q51211949
Recommended placement torque when tightening an orthodontic mini-implant.Q51280828
Clinical outcome of Brånemark System implants of various diameters: a retrospective study.Q52030493
Experimental study of turned and grit-blasted screw-shaped implants with special emphasis on effects of blasting material and surface topographyQ71881038
The relationship of Periotest values, biomaterial, and torque to failure in adult baboonsQ72142261
Torque and histomorphometric evaluation of c.p. titanium screws blasted with 25- and 75-microns-sized particles of Al2O3Q73037168
A prospective multicenter clinical study of the Osseotite implant: four-year interim reportQ73809538
Evaluation of design parameters of osseointegrated dental implants using finite element analysisQ74318434
Histological evaluation of peri-implant bone at implants subjected to occlusal overload or plaque accumulationQ74544270
Mobility assessment with the Periotest system in relation to histologic findings of oral implantsQ74691289
Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory studyQ82491870
Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: is there a relationship? An in vitro studyQ82503411
Immediate rehabilitation of the edentulous mandible with screw type implants: results after up to 10 years of clinical functionQ82548531
Comparison of crestal bone loss and implant stability among the implants placed with conventional procedure and using osteotome technique: a clinical studyQ82808707
Primary stability and self-tapping blades: biomechanical assessment of dental implants in medium-density boneQ83409274
P275copyright licenseCreative Commons Attribution-NonCommercial 3.0 UnportedQ18810331
P6216copyright statuscopyrightedQ50423863
P433issue2
P407language of work or nameEnglishQ1860
P304page(s)115-121
P577publication date2015-04-23
P1433published inThe journal of advanced prosthodonticsQ26842721
P1476titleThe effect of the thread depth on the mechanical properties of the dental implant
P478volume7

Reverse relations

cites work (P2860)
Q54940704Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.
Q90447653Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study
Q42085212Inlay osteotome sinus floor elevation with concentrated growth factor application and simultaneous short implant placement in severely atrophic maxilla
Q92257996Primary Stability Optimization by Using Fixtures with Different Thread Depth According To Bone Density: A Clinical Prospective Study on Early Loaded Implants
Q92554994[Expert consensus on biomechanical research of dental implant]