Degradation of CT Low-Contrast Spatial Resolution Due to the Use of Iterative Reconstruction and Reduced Dose Levels

scientific article published on 26 March 2015

Degradation of CT Low-Contrast Spatial Resolution Due to the Use of Iterative Reconstruction and Reduced Dose Levels is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1148/RADIOL.15142047
P932PMC publication ID4514568
P698PubMed publication ID25811326

P50authorCynthia H McColloughQ49898900
P2093author name stringYi Zhang
Lifeng Yu
Shuai Leng
Rickey E Carter
James M Kofler
Zhoubo Li
P2860cites workThe phantom portion of the American College of Radiology (ACR) computed tomography (CT) accreditation program: practical tips, artifact examples, and pitfalls to avoidQ35919751
Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imagingQ36945865
Abdominal CT: Comparison of Adaptive Statistical Iterative and Filtered Back Projection Reconstruction TechniquesQ37786894
Radiation dose reduction with Sinogram Affirmed Iterative Reconstruction technique for abdominal computed tomographyQ38010636
Methods for clinical evaluation of noise reduction techniques in abdominopelvic CT.Q38229097
A three-dimensional statistical approach to improved image quality for multislice helical CT.Q40145317
Iterative reconstruction algorithm for CT: can radiation dose be decreased while low-contrast detectability is preserved?Q43675732
Effect of reduced radiation exposure and iterative reconstruction on detection of low-contrast low-attenuation lesions in an anthropomorphic liver phantom: an 18-reader studyQ43972327
Contrast-to-noise ratio and low-contrast object resolution on full- and low-dose MDCT: SAFIRE versus filtered back projection in a low-contrast object phantom and in the liverQ47576687
Iterative reconstruction technique for reducing body radiation dose at CT: feasibility studyQ84441385
P433issue2
P407language of work or nameEnglishQ1860
P304page(s)499-506
P577publication date2015-03-26
P1433published inRadiologyQ3285690
P1476titleDegradation of CT Low-Contrast Spatial Resolution Due to the Use of Iterative Reconstruction and Reduced Dose Levels
P478volume276

Reverse relations

cites work (P2860)
Q89677452A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study
Q36248019A cross-platform survey of CT image quality and dose from routine abdomen protocols and a method to systematically standardize image quality
Q64096062A deep learning- and partial least square regression-based model observer for a low-contrast lesion detection task in CT
Q40128439A robust noise reduction technique for time resolved CT.
Q59523381A simple method for low-contrast detectability, image quality and dose optimisation with CT iterative reconstruction algorithms and model observers
Q58588168An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images
Q38942637An effective noise reduction method for multi-energy CT images that exploit spatio-spectral features
Q87848643Application of 80-kVp scan and raw data-based iterative reconstruction for reduced iodine load abdominal-pelvic CT in patients at risk of contrast-induced nephropathy referred for oncological assessment: effects on radiation dose, image quality and
Q38612267Axial or Helical? Considerations for wide collimation CT scanners capable of volumetric imaging in both modes
Q30654523CT brush and CancerZap!: two video games for computed tomography dose minimization
Q39021772CT image quality in sinogram affirmed iterative reconstruction phantom study - is there a point of diminishing returns?
Q37196406Can use of adaptive statistical iterative reconstruction reduce radiation dose in unenhanced head CT? An analysis of qualitative and quantitative image quality
Q38682614Comparison of iterative model, hybrid iterative, and filtered back projection reconstruction techniques in low-dose brain CT: impact of thin-slice imaging.
Q38757585Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.
Q48161713Diagnostic performance of reduced-dose CT with a hybrid iterative reconstruction algorithm for the detection of hypervascular liver lesions: a phantom study
Q92395330Dose and blending fraction quantification for adaptive statistical iterative reconstruction based on low-contrast detectability in abdomen CT
Q38974155Effect of Radiation Dose Reduction and Reconstruction Algorithm on Image Noise, Contrast, Resolution, and Detectability of Subtle Hypoattenuating Liver Lesions at Multidetector CT: Filtered Back Projection versus a Commercial Model-based Iterative R
Q50733888Evaluation of a projection-domain lung nodule insertion technique in thoracic computed tomography.
Q38848416Extracting Information From Previous Full-Dose CT Scan for Knowledge-Based Bayesian Reconstruction of Current Low-Dose CT Images.
Q36949452Impact of number of repeated scans on model observer performance for a low-contrast detection task in computed tomography
Q91623427Improving image quality with model-based iterative reconstruction at quarter of nominal dose in upper abdominal CT
Q51746717Influence of CT acquisition and reconstruction parameters on radiomic feature reproducibility.
Q38646627Influence of exposure parameters and iterative reconstruction on automatic airway segmentation and analysis on MDCT-An ex vivo phantom study
Q39684508Low contrast detectability and spatial resolution with model-based Iterative reconstructions of MDCT images: a phantom and cadaveric study
Q42315691Low-dose CT imaging of a total hip arthroplasty phantom using model-based iterative reconstruction and orthopedic metal artifact reduction
Q47558364Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT.
Q58706299Reduction of the radiation dose and the amount of contrast material in hepatic dynamic CT using low tube voltage and adaptive iterative dose reduction 3-dimensional
Q90687235Spectral CT Reconstruction via Low-rank Representation and Region-specific Texture Preserving Markov Random Field Regularization
Q64096314Understanding, justifying, and optimizing radiation exposure for CT imaging in nephrourology
Q47659809Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images

Search more.