A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

scientific article published on February 2016

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1118/1.4940355
P8608Fatcat IDrelease_rk67ifzby5e7nige6i5b27mkja
P932PMC publication ID4733082
P698PubMed publication ID26843254
P5875ResearchGate publication ID291970107

P2093author name stringSimon R Cherry
Eric Berg
Junwei Du
Emilie Roncali
Maciej Kapusta
P2860cites workHypothalamic-pituitary-adrenal axis, neuroendocrine factors and stressQ28207285
Tapered LSO arrays for small animal PET.Q35051998
Pulse shape discrimination and classification methods for continuous depth of interaction encoding PET detectorsQ36351847
Benefit of time-of-flight in PET: experimental and clinical resultsQ37091456
Optimal whole-body PET scanner configurations for different volumes of LSO scintillator: a simulation studyQ37206739
State of the art and challenges of time-of-flight PET.Q37356191
Continuous depth-of-interaction encoding using phosphor-coated scintillatorsQ37357704
Ultra staging to unmask the prescribing of adjuvant therapy in cancer patients: the future opportunity to image micrometastases using total-body 18F-FDG PET scanningQ39236654
Predicting the timing properties of phosphor-coated scintillators using Monte Carlo light transport simulationQ41107087
Physical and clinical performance of the mCT time-of-flight PET/CT scannerQ43958296
Timing properties of phosphor-coated polished LSO crystals.Q45970053
Depth of interaction resolution measurements for a high resolution PET detector using position sensitive avalanche photodiodesQ46707067
Scintillation CameraQ56442812
P433issue2
P407language of work or nameEnglishQ1860
P1104number of pages12
P304page(s)939-950
P577publication date2016-02-01
P1433published inMedical PhysicsQ15764251
P1476titleA combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography
P478volume43

Reverse relations

cites work (P2860)
Q42078248Depth of interaction determination in monolithic scintillator with double side SiPM readout
Q50054045Development and evaluation of mini-EXPLORER: a long axial field-of-view PET scanner for non-human primate imaging
Q92097219Feasibility of Using Crystal Geometry for a DOI Scintillation Detector
Q57178975Innovations in Instrumentation for Positron Emission Tomography
Q90254416Multiplexed imaging for diagnosis and therapy
Q47116938Parallax error in long-axial field-of-view PET scanners-a simulation study
Q46190560Reaching 200-ps timing resolution in a time-of-flight and depth-of-interaction positron emission tomography detector using phosphor-coated crystals and high-density silicon photomultipliers
Q48649612Time-over-threshold for pulse shape discrimination in a time-of-flight phoswich PET detector

Search more.