Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network

scientific article published on March 2004

Accuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.2337/DIACARE.27.3.722
P932PMC publication ID2365475
P698PubMed publication ID14988292

P50authorDiabetes Research in Children Network Study GroupQ65054857
P2860cites workNoninvasive glucose monitoring: comprehensive clinical results. Cygnus Research TeamQ28138594
Analysis of continuous glucose monitoring data from non-diabetic and diabetic children: a tale of two algorithmsQ30807333
Glucose monitoring by reverse iontophoresisQ34580971
The accuracy of the CGMS in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy studyQ36473851
The accuracy of the GlucoWatch G2 biographer in children with type 1 diabetes: results of the diabetes research in children network (DirecNet) accuracy studyQ36549188
Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogsQ40603108
Detection of hypoglycemia with the GlucoWatch biographerQ43603793
Clinical evaluation of the GlucoWatch biographer: a continual, non-invasive glucose monitor for patients with diabetesQ43778625
Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetesQ43778825
Reproducibility of glucose measurements using the glucose sensor.Q44043331
Spurious reporting of nocturnal hypoglycemia by CGMS in patients with tightly controlled type 1 diabetesQ44114796
Nocturnal hypoglycemia detected with the Continuous Glucose Monitoring System in pediatric patients with type 1 diabetes.Q44200775
Hypoglycemia prevalence in prepubertal children with type 1 diabetes on standard insulin regimen: use of continuous glucose monitoring systemQ44333441
Use of the GlucoWatch biographer in children and adolescents with diabetesQ44796592
Effect of acetaminophen on the accuracy of glucose measurements obtained with the GlucoWatch biographerQ46109878
Intellectual deficits associated with early onset of insulin-dependent diabetes mellitus in childrenQ48959443
Fear of hypoglycemia in the parents of children and adolescents with diabetes: maladaptive or healthy response?Q51103513
The effect of hypoglycemic seizures on cognitive function in children with diabetes: a 7-year prospective study.Q52034720
Correlation of fingerstick blood glucose measurements with GlucoWatch biographer glucose results in young subjects with type 1 diabetes.Q52380609
Effect of intensive diabetes treatment on the development and progression of long-term complications in adolescents with insulin-dependent diabetes mellitus: Diabetes Control and Complications Trial. Diabetes Control and Complications Trial ResearchQ72082832
P433issue3
P407language of work or nameEnglishQ1860
P921main subjectglucose monitoringQ95987978
hypoglycemiaQ202758
P304page(s)722-726
P577publication date2004-03-01
P1433published inDiabetes CareQ5270111
P1476titleAccuracy of the GlucoWatch G2 Biographer and the continuous glucose monitoring system during hypoglycemia: experience of the Diabetes Research in Children Network
P478volume27

Reverse relations

cites work (P2860)
Q46098687Application of muscle biopotential measurement for sustained, noninvasive blood glucose survey
Q26823654Biocompatible materials for continuous glucose monitoring devices
Q38440475Blood, sweat, and tears: developing clinically relevant protein biosensors for integrated body fluid analysis.
Q33874017Carbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
Q40383846Continuous glucose monitoring has left the station: are you onboard?
Q84957349Continuous glucose monitoring in insulin pump treated children
Q46637181Continuous glucose monitoring system in the screening of early glucose derangements in children and adolescents with cystic fibrosis.
Q24187648Continuous glucose monitoring systems for type 2 diabetes mellitus
Q24235570Continuous glucose monitoring systems for type 2 diabetes mellitus
Q31155907Diabetes research in children network:availability of protocol data sets
Q36167654Disease management in the young diabetic patient: glucose monitoring, coping skills, and treatment strategies
Q37130412Educating families on real time continuous glucose monitoring: the DirecNet navigator pilot study experience
Q36904764Electrochemical Sensors for Clinic Analysis
Q36457316Enzymatic biosensors
Q36549174GlucoWatch G2 Biographer alarm reliability during hypoglycemia in children
Q46625427How the continuous glucose monitoring system can contribute to HbA1c interpretation in type 1 diabetes mellitus?
Q38452793Hypo- and Hyperglycemic Alarms: Devices and Algorithms
Q39899500Hypoglycemia prediction with subject-specific recursive time-series models
Q36481923Impact of exercise on overnight glycemic control in children with type 1 diabetes mellitus
Q46344075Is silent hypoglycemia part of ideal glycemic control in DM1 patients? - hypoglycemic state by CGMS vs. glycemic average
Q36471290Lack of accuracy of continuous glucose sensors in healthy, nondiabetic children: results of the Diabetes Research in Children Network (DirecNet) accuracy study
Q35651936Limitations of statistical measures of error in assessing the accuracy of continuous glucose sensors
Q42947362Patients’ evaluation of nocturnal hypoglycaemia with GlucoDay continuous glucose monitoring in paediatric patients
Q34407187Psychological aspects of continuous glucose monitoring in pediatric type 1 diabetes
Q34696490Response to nocturnal alarms using a real-time glucose sensor
Q36857631Simultaneous transdermal extraction of glucose and lactate from human subjects by reverse iontophoresis
Q37727804State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes-The Need for Novel Non-Invasive Techniques
Q42598674Statistical hypoglycemia prediction
Q37815571Technologies for continuous glucose monitoring: current problems and future promises
Q36335181Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies
Q34482263Youth and parent satisfaction with clinical use of the GlucoWatch G2 Biographer in the management of pediatric type 1 diabetes
Q82861459[Continuous glucose monitoring: a critical appraisal after one year experience]