scholarly article | Q13442814 |
P50 | author | Nikhil Paliwal | Q49751234 |
Xinjian Yang | Q58326702 | ||
P2093 | author name string | Hui Meng | |
Haiyun Li | |||
Hongyu Yu | |||
Jianping Xiang | |||
Adnan Siddiqui | |||
Jinhui Xu | |||
P2860 | cites work | Early Experience in the Treatment of Intra-Cranial Aneurysms by Endovascular Flow Diversion: A Multicentre Prospective Study | Q21089997 |
Long-term angiographic recurrences after selective endovascular treatment of aneurysms with detachable coils | Q34201386 | ||
High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: in vitro and in silico | Q37154373 | ||
Comparison of two stents in modifying cerebral aneurysm hemodynamics. | Q37232360 | ||
Alteration of intra-aneurysmal hemodynamics for flow diversion using enterprise and vision stents | Q37825408 | ||
Finite element modeling of endovascular coiling and flow diversion enables hemodynamic prediction of complex treatment strategies for intracranial aneurysm | Q39268511 | ||
Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms | Q39519001 | ||
Fast virtual deployment of self-expandable stents: method and in vitro evaluation for intracranial aneurysmal stenting. | Q39941632 | ||
Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics. | Q40543516 | ||
Association between hemodynamic conditions and occlusion times after flow diversion in cerebral aneurysms. | Q44996268 | ||
Panacea or problem: flow diverters in the treatment of symptomatic large or giant fusiform vertebrobasilar aneurysms | Q46454730 | ||
Which spring is the best? Comparison of methods for virtual stenting | Q47756325 | ||
Efficient simulation of blood flow past complex endovascular devices using an adaptive embedding technique | Q48933449 | ||
Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up. | Q50907989 | ||
Increasing flow diversion for cerebral aneurysm treatment using a single flow diverter. | Q51732163 | ||
4D deformable models with temporal constraints: application to 4D cardiac image segmentation. | Q53602066 | ||
Computer modeling of deployment and mechanical expansion of neurovascular flow diverter in patient-specific intracranial aneurysms | Q84594733 | ||
Flow diversion treatment: intra-aneurismal blood flow velocity and WSS reduction are parameters to predict aneurysm thrombosis | Q84881213 | ||
Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms | Q84977008 | ||
Enhanced aneurysmal flow diversion using a dynamic push-pull technique: an experimental and modeling study | Q87747890 | ||
P433 | issue | 13 | |
P407 | language of work or name | English | Q1860 |
P921 | main subject | workflow | Q627335 |
P304 | page(s) | 1423-1431 | |
P577 | publication date | 2016-02-22 | |
P1433 | published in | Computer Methods in Biomechanics and Biomedical Engineering | Q15751255 |
P1476 | title | Virtual stenting workflow with vessel-specific initialization and adaptive expansion for neurovascular stents and flow diverters | |
P478 | volume | 19 |
Q38609233 | A New Imaging Tool for Realtime Measurement of Flow Velocity in Intracranial Aneurysms |
Q91833879 | A novel virtual flow diverter implantation method with realistic deployment mechanics and validated force response |
Q37114291 | Analysis of Multiple Intracranial Aneurysms with Different Outcomes in the Same Patient After Endovascular Treatment |
Q33686063 | Association between hemodynamic modifications and clinical outcome of intracranial aneurysms treated using flow diverters. |
Q64880188 | Efficacy of LVIS vs. Enterprise Stent for Endovascular Treatment of Medium-Sized Intracranial Aneurysms: A Hemodynamic Comparison Study. |
Q99406127 | Efficient simulation of a low-profile visualized intraluminal support device: a novel fast virtual stenting technique |
Q47772044 | Flow Diversion and Outcomes of Vertebral Fusiform Aneurysms After Stent-Only Treatment: A Hemodynamic Study. |
Q38787539 | Haemodynamic analysis for recanalisation of intracranial aneurysms after endovascular treatment: an observational registry study in China |
Q40017165 | Hemodynamic Effect of Flow Diverter and Coils in Treatment of Large and Giant Intracranial Aneurysms |
Q93215197 | Outcome prediction of intracranial aneurysm treatment by flow diverters using machine learning |
Q91638327 | Patency of Posterior Circulation Branches Covered by Flow Diverter Device: A Hemodynamic Study |
Q51731113 | Predicting Successful Treatment of Intracranial Aneurysms with the Pipeline Embolization Device through Meta-Regression. |
Q50348874 | Predisposing factors for recanalization of cerebral aneurysms after endovascular embolization: a multivariate study |
Q41941578 | Rapid Virtual Stenting for Intracranial Aneurysms. |
Q49750476 | Successful Retreatment of Recurrent Intracranial Vertebral Artery Dissecting Aneurysms After Stent-Assisted Coil Embolization: A Self-Controlled Hemodynamic Analysis. |
Search more.