Elastoplasty as a promising novel technique: Vertebral augmentation with an elastic silicone-based polymer

scientific article published on 12 February 2017

Elastoplasty as a promising novel technique: Vertebral augmentation with an elastic silicone-based polymer is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1016/J.AOTT.2017.01.001
P932PMC publication ID6197590
P698PubMed publication ID28202221

P50authorStefano BorianiQ33304031
Yunus Emre AkmanQ57020084
Alessandro GasbarriniQ72080967
P2093author name stringRiccardo Ghermandi
Marco Girolami
P2860cites workPercutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspectsQ30471435
Does vertebroplasty cause incident vertebral fractures? A review of available data.Q31054263
Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplastyQ35904276
Incidence of subsequent vertebral fracture after kyphoplasty.Q35916199
The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty.Q35916355
Adjacent vertebral failure after vertebroplasty: a biomechanical study of low-modulus PMMA cement.Q36274761
Effect of bone cement volume and stiffness on occurrences of adjacent vertebral fractures after vertebroplastyQ36514789
Percutaneous vertebroplasty as a treatment for osteoporotic vertebral compression fractures: a systematic reviewQ36528586
Refractures in cemented vertebrae after percutaneous vertebroplasty: a retrospective analysisQ36542614
Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studiesQ36573314
Subsequent vertebral fracture after vertebroplasty: incidence and analysis of risk factorsQ37829306
Elastoplasty: first experience in 12 patientsQ39247631
Effect of vertebroplasty on pain relief, quality of life, and the incidence of new vertebral fractures: a 12-month randomized follow-up, controlled trial.Q39249043
Dose-dependent epidural leakage of polymethylmethacrylate after percutaneous vertebroplasty in patients with osteoporotic vertebral compression fractures.Q39411040
Elastoplasty: A Silicon Polymer as a New Filling Material for Kyphoplasty in Comparison to PMMA.Q39563715
Load shift of the intervertebral disc after a vertebroplasty: a finite-element studyQ42223394
Biomechanical comparison of vertebral augmentation with silicone and PMMA cement and two filling gradesQ42860749
Incidence of symptomatic vertebral fractures in patients after percutaneous vertebroplastyQ43559340
Adjacent vertebral body fracture following vertebroplasty with polymethylmethacrylate or calcium phosphate cement: biomechanical evaluation of the cadaveric spineQ44415887
Repeated and multiple new vertebral compression fractures after percutaneous transpedicular vertebroplasty.Q44641476
Preventive vertebroplasty for adjacent vertebral bodies: a good solution to reduce adjacent vertebral fracture after percutaneous vertebroplasty.Q45029357
Effects of bone cement volume and distribution on vertebral stiffness after vertebroplastyQ46063009
Frequency and outcome of pulmonary polymethylmethacrylate embolism during percutaneous vertebroplastyQ46342076
The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysisQ47885407
Vertebroplasty increases trabecular microfractures in elderly female cadaver spines.Q51041976
The validation of visual analogue scales as ratio scale measures for chronic and experimental pain.Q51240433
Premature adjacent vertebral fracture after vertebroplasty: a biomechanical study.Q51578223
Prophylactic vertebroplasty may reduce the risk of adjacent intact vertebra from fatigue injury: an ex vivo biomechanical study.Q53369144
Prophylactic vertebroplasty can decrease the fracture risk of adjacent vertebrae: an in vitro cadaveric study.Q53573232
Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: an open prospective study.Q53923304
[Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty]Q69079983
The biomechanics of vertebroplasty. The effect of cement volume on mechanical behaviorQ74230818
Recollapse of previous vertebral compression fracture after percutaneous vertebroplastyQ81659981
New fractures after vertebroplasty: adjacent fractures occur significantly soonerQ82285835
Prophylactic vertebroplasty: cement injection into non-fractured vertebral bodies during percutaneous vertebroplastyQ83148661
Is vertebroplasty a risk factor for subsequent vertebral fracture, meta-analysis of published evidence?Q87643392
Severe kyphotic deformity resulting from collapses of cemented and adjacent vertebrae following percutaneous vertebroplasty using calcium phosphate cement. A case reportQ87991077
P433issue3
P407language of work or nameEnglishQ1860
P304page(s)209-214
P577publication date2017-02-12
P1433published inActa Orthopaedica et Traumatologica TurcicaQ4676738
P1476titleElastoplasty as a promising novel technique: Vertebral augmentation with an elastic silicone-based polymer
P478volume51

Reverse relations

Q38635291Percutaneous Vertebroplasty and Kyphoplasty: Current Status, New Developments and Old Controversiescites workP2860

Search more.