Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter

scientific article

Characteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1111/JCE.13087
P698PubMed publication ID27569722

P2093author name stringKevin Ng
Gerald C Kaye
Paul A Gould
Kieran Dauber
Andrew Claughton
Cameron Booth
P2860cites workEFFICAS II: optimization of catheter contact force improves outcome of pulmonary vein isolation for paroxysmal atrial fibrillationQ35950566
Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASQ38406337
Effect of catheter ablation on progression of paroxysmal atrial fibrillationQ38427159
Long-term outcomes after catheter ablation of cavo-tricuspid isthmus dependent atrial flutter: a meta-analysisQ43266232
Electrical reconnection after pulmonary vein isolation is contingent on contact force during initial treatment: results from the EFFICAS I studyQ43780937
Catheter-tissue contact force determines atrial electrogram characteristics before and lesion efficacy after antral pulmonary vein isolation in humansQ44320557
Characterization of the impact of catheter-tissue contact force in lesion formation during cavo-tricuspid isthmus ablation in an experimental swine modelQ46422570
Unipolar electrogram morphology to assess lesion formation during catheter ablation of atrial fibrillation: successful translation into clinical practiceQ46758759
Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombusQ47172700
Effect of respiration on catheter-tissue contact force during ablation of atrial arrhythmiasQ48186219
Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values.Q53088695
Results From the Loire-Ardèche-Drôme-Isère-Puy-de-Dôme (LADIP) Trial on Atrial Flutter, a Multicentric Prospective Randomized Study Comparing Amiodarone and Radiofrequency Ablation After the First Episode of Symptomatic Atrial FlutterQ57803720
P433issue12
P921main subjectcatheter ablationQ436572
catheterizationQ2312472
P304page(s)1429-1436
P577publication date2016-08-29
P1433published inJournal of Cardiovascular ElectrophysiologyQ4736917
P1476titleCharacteristics of Cavotricuspid Isthmus Ablation for Atrial Flutter Guided by Novel Parameters Using a Contact Force Catheter
P478volume27

Reverse relations

cites work (P2860)
Q48096702The waiting period following cavotricuspid isthmus ablation: Opportunity for watchful observation or a waste of time?
Q55312059Use of microelectrode near-field signals to determine catheter contact.