A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers

scientific article published on 31 October 2008

A performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1016/J.ULTRAS.2008.10.012
P698PubMed publication ID19100591
P5875ResearchGate publication ID223024240

P2093author name stringA Ramos
A Vera
L Leija
M Vazquez
I Bazán
P2860cites workA multi-gate time-of-flight technique for estimation of temperature distribution in heated tissue: theory and computer simulationQ30671520
Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermiaQ35127105
Introduction: radiosensitization by hyperthermiaQ35804047
Non-invasive estimation of hyperthermia temperatures with ultrasoundQ36251219
Hyperthermia induces differentiation without apoptosis in permissive temperatures in human erythroleukaemia cellsQ40431340
A wall-less vessel phantom for Doppler ultrasound studiesQ41000349
Statistical properties of radio-frequency and envelope-detected signals with applications to medical ultrasoundQ42627370
Development of an electrical impedance tomography system for noninvasive temperature monitoring of hyperthermia treatments.Q43572224
An analysis of lesion development in the brain and in plastics by high-intensity focused ultrasound at low-megahertz frequenciesQ48777535
Noninvasive estimation of tissue temperature via high-resolution spectral analysis techniques.Q48954440
Two-dimensional temperature estimation using diagnostic ultrasoundQ50248732
Fundamental limitations of noninvasive temperature imaging by means of ultrasound echo strain estimationQ50251056
Differential attenuation imaging for the characterization of high intensity focused ultrasound lesionsQ50252552
Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part I. Analytical modelQ50253015
Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose.Q52261266
Noninvasive temperature estimation in tissue via ultrasound echo-shifts. Part II. In vitro study.Q52295855
A model for ultrasonic scattering from tissues based on the K distribution.Q52328599
Development of an example flow test object and comparison of five of these test objects, constructed in various laboratories.Q52903555
Application of autoregressive spectral analysis to cepstral estimation of mean scatterer spacing.Q54249969
Ultrasonic backscattering from human tissue: a realistic modelQ67568725
An easily made ultrasound biopsy phantomQ68873586
A new ultrasound tissue-equivalent materialQ71130654
Thermal properties of tissue equivalent phantom materialsQ71392639
Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasoundQ71976490
Modeling acoustic backscatter from kidney microstructure using an anisotropic correlation functionQ72556981
The changes in acoustic attenuation due to in vitro heatingQ73043788
Performance of time delay estimation methods for small time shifts in ultrasonic signalsQ73669884
Dependence of pulser driving responses on electrical and motional characteristics of NDE ultrasonic probesQ73830818
Non-invasive microwave radiometry thermometryQ74647743
Attenuation coefficient and propagation speed estimates of rat and pig intercostal tissue as a function of temperatureQ78436554
Optimization of electromagnetic phased-arrays for hyperthermia via magnetic resonance temperature estimationQ78568989
Ultrasound properties of human prostate tissue during heatingQ78617241
PSpice circuital modelling of ultrasonic imaging transceivers including frequency-dependent acoustic losses and signal distortions in electronic stagesQ79782601
Temperature dependence of ultrasonic propagation speed and attenuation in excised canine liver tissue measured using transmitted and reflected pulsesQ80294998
Studies on ultrasonic scattering from quasi-periodic structuresQ80617010
Nonuniform phase distribution in ultrasound speckle analysis. II. Parametric expression and a frequency sweeping technique to measure mean scatterer spacingQ80680732
Spectral characterization of tissues microstructure by ultrasounds: a stochastic approachQ80732019
P433issue3
P304page(s)358-376
P577publication date2008-10-31
P1433published inUltrasonicsQ2456507
P1476titleA performance analysis of echographic ultrasonic techniques for non-invasive temperature estimation in hyperthermia range using phantoms with scatterers
P478volume49

Reverse relations

cites work (P2860)
Q30441041A new high-resolution spectral approach to noninvasively evaluate wall deformations in arteries.
Q30370619Calibration Method of an Ultrasonic System for Temperature Measurement.
Q30459260Estimation of PSD shifts for high-resolution metrology of thickness micro-changes with possible applications in vessel walls and biological membrane characterization.
Q51397839Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.
Q51645180In Vivo Noninvasive Temperature Measurement by B-Mode Ultrasound Imaging
Q91990545Method for estimating average grey-level's measurement uncertainty from ultrasound images for non-invasive estimation of temperature in different tissue types
Q30467270Possible patient early diagnosis by ultrasonic noninvasive estimation of thermal gradients into tissues based on spectral changes modeling.
Q52684822Power spectral estimation of high-harmonics in echoes of wall resonances to improve resolution in non-invasive measurements of wall mechanical properties in rubber tube and ex-vivo artery.
Q36272259Temperature monitoring by channel data delays: Feasibility based on estimated delays magnitude for cardiac ablation.
Q64900785The Effect of Tissue-Mimicking Phantom Compressibility on Magnetic Hyperthermia.
Q28080996Thermometry and ablation monitoring with ultrasound.
Q50902901Ultrasonic temperature distribution reconstruction for circular area based on Markov radial basis approximation and singular value decomposition.
Q42360693Uncertainty estimation for temperature measurement with diagnostic ultrasound.

Search more.