Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: insights from lung tumor patients treated with robotic radiosurgery

scientific article published on March 2015

Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: insights from lung tumor patients treated with robotic radiosurgery is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1118/1.4907956
P698PubMed publication ID25735283
P5875ResearchGate publication ID273152838

P50authorSue S. YomQ38327769
P2093author name stringJean Pouliot
Christopher McGuinness
Josephine Chen
Martina Descovich
Alexander R Gottschalk
Dilini Pinnaduwage
Danita Kannarunimit
Norbert Kased
P2860cites workClinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log filesQ33429378
Complications associated with the percutaneous insertion of fiducial markers in the thoraxQ34293938
Image-guided robotic stereotactic radiation therapy with fiducial-free tumor tracking for lung cancerQ36202965
CyberKnife Stereotactic Ablative Radiotherapy for Lung TumorsQ37808696
Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking systemQ39715367
The management of respiratory motion in radiation oncology report of AAPM Task Group 76.Q44924583
A study of the accuracy of cyberknife spinal radiosurgery using skeletal structure trackingQ46412194
The effects of target size and tissue density on the minimum margin required for random errors.Q47398786
SU-E-T-422: Lung SBRT Using Cyberknife: Technique and Treatment OutcomeQ48787176
Four-dimensional computed tomography-based interfractional reproducibility study of lung tumor intrafractional motionQ50128922
The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.Q51644928
Quantifying interfraction and intrafraction tumor motion in lung stereotactic body radiotherapy using respiration-correlated cone beam computed tomography.Q51836465
Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance.Q51861377
Incidence of changes in respiration-induced tumor motion and its relationship with respiratory surrogates during individual treatment fractions.Q53428825
P433issue3
P407language of work or nameEnglishQ1860
P304page(s)1280-1287
P577publication date2015-03-01
P1433published inMedical PhysicsQ15764251
P1476titleComparison between target margins derived from 4DCT scans and real-time tumor motion tracking: insights from lung tumor patients treated with robotic radiosurgery
P478volume42

Reverse relations

cites work (P2860)
Q374170994DCT and CBCT based PTV margin in Stereotactic Body Radiotherapy(SBRT) of non-small cell lung tumor adhered to chest wall or diaphragm
Q47877896A phase I/II study on stereotactic body radiotherapy with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm for lung tumors
Q54983041Clinical Results of Mean GTV Dose Optimized Robotic-Guided Stereotactic Body Radiation Therapy for Lung Tumors.
Q58804492Cyberknife stereotactic radiation therapy for stage I lung cancer and pulmonary metastases: evaluation of local control at 24 months
Q93083095Dosimetric Effect of Intrafraction Tumor Motion in Lung Stereotactic Body Radiotherapy Using CyberKnife Static Tracking System
Q40661837Evaluating the four-dimensional cone beam computed tomography with varying gantry rotation speed
Q55340298Evaluation of the intra- and interfractional tumor motion and variability by fiducial-based real-time tracking in liver stereotactic body radiation therapy.
Q88490364Influence of respiratory motion management technique on radiation pneumonitis risk with robotic stereotactic body radiation therapy
Q41534152Target margin design for real-time lung tumor tracking stereotactic body radiation therapy using CyberKnife Xsight Lung Tracking System
Q90376507Tracking, gating, free-breathing, which technique to use for lung stereotactic treatments? A dosimetric comparison