4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam CT.

scientific article published on 22 July 2012

4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam CT. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1093/JRR/RRS058
P932PMC publication ID3534265
P698PubMed publication ID22843380
P5875ResearchGate publication ID230585774

P50authorKeiichi NakagawaQ47273059
Satoshi KidaQ108923281
P2093author name stringKuni Ohtomo
Yoshitaka Masutani
Akihiro Haga
Hideomi Yamashita
Wataru Takahashi
Kiyoshi Yoda
Yoshio Iwai
Akira Sakumi
Naoya Saotome
Takashi Shiraki
P2860cites workThe in vivo study on the radiobiologic effect of prolonged delivery time to tumor control in C57BL mice implanted with Lewis lung cancer.Q34510303
Current status and future perspective of flattening filter free photon beamsQ37869113
4D digitally reconstructed radiography for verifying a lung tumor position during volumetric modulated arc therapyQ41910922
Cone beam computed tomography data acquisition during VMAT delivery with subsequent respiratory phase sorting based on projection image cross-correlationQ43879000
Development of a four-dimensional image-guided radiotherapy system with a gimbaled X-ray headQ48931287
Real-time tumour-tracking radiotherapyQ49083493
Respiratory correlated cone beam CT.Q51465798
Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients.Q51936791
The use of active breathing control (ABC) to reduce margin for breathing motionQ61903157
Irradiation synchronized with respiration gateQ69723013
Respiratory gated beam delivery cannot facilitate margin reduction, unless combined with respiratory correlated image guidanceQ80028768
P433issue1
P304page(s)152-156
P577publication date2012-07-22
P1433published inJournal of Radiation ResearchQ2330802
P1476title4D registration and 4D verification of lung tumor position for stereotactic volumetric modulated arc therapy using respiratory-correlated cone-beam CT.
P478volume54

Reverse relations

cites work (P2860)
Q40156372A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections
Q90449396Advanced 4-dimensional cone-beam computed tomography reconstruction by combining motion estimation, motion-compensated reconstruction, biomechanical modeling and deep learning
Q58804831Advances in the use of motion management and image guidance in radiation therapy treatment for lung cancer
Q40502208Cone-beam CT reconstruction for non-periodic organ motion using time-ordered chain graph model
Q92581872Contrast media-assisted in-treatment cone beam CT during single-isocentre volumetric-modulated arc therapy for multiple brain metastases: a case study
Q58584484Development of a markerless tumor-tracking algorithm using prior four-dimensional cone-beam computed tomography
Q39025274Estimating 4D-CBCT from prior information and extremely limited angle projections using structural PCA and weighted free-form deformation for lung radiotherapy
Q55110451Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique.
Q53052133Frameless stereotactic body radiation therapy for multiple lung metastases.
Q42751946Impact of flattening-filter-free techniques on delivery time for lung stereotactic volumetric modulated arc therapy and image quality of concurrent kilovoltage cone-beam computed tomography: a preliminary phantom study.
Q42816178Lung tumor motion reproducibility for five patients who received four-fraction VMAT stereotactic ablative body radiotherapy under constrained breathing conditions: a preliminary study
Q45784789Motion-map constrained image reconstruction (MCIR): application to four-dimensional cone-beam computed tomography
Q51028548Optimization of acquisition parameters and accuracy of target motion trajectory for four-dimensional cone-beam computed tomography with a dynamic thorax phantom.
Q61804648Optimizing immobilization, margins, and imaging for lung stereotactic body radiation therapy
Q47110081Preliminary comparison of the registration effect of 4D-CBCT and 3D-CBCT in image-guided radiotherapy of Stage IA non-small-cell lung cancer
Q38256158Radiation pneumonitis after stereotactic radiation therapy for lung cancer
Q90697953Salvage stereotactic body radiotherapy for post-operative oligo-recurrence of non-small cell lung cancer: A single-institution analysis of 59 patients
Q64917835Stereotactic body radiotherapy for centrally-located lung tumors with 56 Gy in seven fractions: A retrospective study.
Q42033188Stereotactic body radiotherapy for small lung tumors in the University of Tokyo Hospital
Q42314440Tumor motion changes in stereotactic body radiotherapy for liver tumors: an evaluation based on four-dimensional cone-beam computed tomography and fiducial markers