Real time kinetic analysis of the interaction between immunoglobulin G and histidine using quartz crystal microbalance biosensor in solution

scientific article published in October 2003

Real time kinetic analysis of the interaction between immunoglobulin G and histidine using quartz crystal microbalance biosensor in solution is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1016/S0956-5663(03)00090-3
P698PubMed publication ID12896844
P5875ResearchGate publication ID10631026

P50authorDihua ShangguanQ42720719
P2093author name stringYang Liu
Rui Zhao
Xiao Yu
Guoquan Liu
Zuyi Bo
P2860cites workDetermination of phage antibody affinities to antigen by a microbalance sensor systemQ30637387
Quartz crystal microbalance (QCM) as a device for the screening of phage librariesQ30658592
Using self-assembled monolayers to understand the interactions of man-made surfaces with proteins and cells.Q41107758
Comparison of different protein immobilization methods on quartz crystal microbalance surface in flow injection immunoassay.Q43813464
Real-time competitive kinetic analysis of interactions between low-molecular-weight ligands in solution and surface-immobilized receptorsQ47370870
Surface modifications for the development of piezoimmunosensors.Q47920405
Evaluation of antibody immobilization methods for piezoelectric biosensor applicationQ50116863
Thiolated Salmonella antibody immobilization onto the gold surface of piezoelectric quartz crystalQ50128508
Real-time immunoassay of antibody activity in serum by surface plasmon resonance biosensor.Q51570540
Competition BIAcore for measuring true affinities: large differences from values determined from binding kinetics.Q52310418
Determination of rate and equilibrium binding constants for macromolecular interactions using surface plasmon resonance: use of nonlinear least squares analysis methods.Q52392958
Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur MikrowägungQ56483227
The Quartz Crystal Microbalance as Biosensor. A Status Report on Its FutureQ58263788
A Piezoelectric Quartz Crystal Biosensor as a Direct Affinity SensorQ58265692
A New Approach to the Development of a Reusable Piezoelectric Crystal BiosensorQ58307490
Separation of immunoglobulin G by high-performance pseudo-bioaffinity chromatography with immobilized histidine. I. Preliminary report on the influence of the silica support and the coupling modeQ67509378
Direct immunochemical sensing: basic chemical principles and fundamental limitationsQ69439847
Preparation of adsorbents for biospecific affinity chromatography. Attachment of group-containing ligands to insoluble polymers by means of bifuctional oxiranesQ69756705
Piezoelectric immunosensor for the detection of immunoglobulin MQ70880777
Characterization of monoclonal antibodies to 2,4-dichlorophenoxyacetic acid using a piezoelectric quartz crystal microbalance in solutionQ72813034
Immunodetection by quartz crystal microbalance. A new approach for direct detection of rabbit IgG and peroxidaseQ73515044
Self-assembling of glutathione S-transferase/calmodulin fusion protein on chemically modified gold surfaceQ73532497
An on-line quantitative immunoassay system based on a quartz crystal microbalanceQ73815758
Biotinylated steroid derivatives as ligands for biospecific interaction analysis with monoclonal antibodies using immunosensor devicesQ73937856
Use of a quartz crystal microbalance to monitor immunoliposome--antigen interactionQ74120399
A strategy for the generation of surfaces presenting ligands for studies of binding based on an active ester as a common reactive intermediate: a surface plasmon resonance studyQ74530881
P433issue11
P407language of work or nameEnglishQ1860
P921main subjectbiosensorQ669391
P1104number of pages9
P304page(s)1419-1427
P577publication date2003-10-01
P1433published inBiosensors & BioelectronicsQ2904235
P1476titleReal time kinetic analysis of the interaction between immunoglobulin G and histidine using quartz crystal microbalance biosensor in solution
P478volume18