Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?

scientific article published on 16 February 2013

Ultrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches? is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1007/S10877-013-9437-6
P698PubMed publication ID23417581

P2093author name stringKamil Toker
Mine Solak
Alparslan Kus
Yavuz Gurkan
Derya Berk
Halim Ulugol
P2860cites workClinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicineQ24798461
Ultrasound-guided catheterization of the radial artery: a systematic review and meta-analysis of randomized controlled trialsQ37781235
Incidence of posterior vessel wall puncture during ultrasound-guided vessel cannulation in a simulated modelQ37808680
Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approachQ38487711
A prospective comparison of ultrasound-guided and blindly placed radial arterial cathetersQ39773756
The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous cathetersQ44740025
Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomised controlled trial.Q48280464
Ultrasound guidance versus the landmark technique for the placement of central venous catheters in the emergency departmentQ50109811
Short-axis versus long-axis approaches for teaching ultrasound-guided vascular access on a new inanimate model.Q51791656
Delayed ischaemia of the hand necessitating amputation after radial artery cannulationQ70646305
Use of ultrasound guidance in the insertion of radial artery cathetersQ78954253
Use of ultrasonography as a rescue technique for failed radial artery cannulationQ82964096
[Ultrasound guided radial artery cannulation: procedure description and literature review]Q83266968
[Comparison of ultrasound-guided and blindly placed radial artery catheterization]Q83632944
P433issue3
P304page(s)319-324
P577publication date2013-02-16
P1433published inJournal of Clinical Monitoring and ComputingQ5310493
P1476titleUltrasound-guided radial arterial cannulation: long axis/in-plane versus short axis/out-of-plane approaches?
P478volume27

Reverse relations

cites work (P2860)
Q52674896Comparison between the long-axis/in-plane and short-axis/out-of-plane approaches for ultrasound-guided vascular catheterization: an updated meta-analysis and trial sequential analysis.
Q47635300Comparison of in-plane and out-of-plane needle insertion with vs. without needle guidance
Q40530045Comparison of short-axis out-of-plane versus long-axis in-plane ultrasound-guided radial arterial cannulation in adult patients: a randomized controlled trial.
Q58775837Comparison of speckleplethysmographic (SPG) and photoplethysmographic (PPG) imaging by Monte Carlo simulations and in vivo measurements
Q36073103Effect of bevel direction on the success rate of ultrasound-guided radial arterial catheterization
Q94586040Efficacy of ultrasound-guided technique for radial artery catheterization in pediatric populations: a systematic review and meta-analysis of randomized controlled trials
Q47925850Forty-five degree wrist angulation is optimal for ultrasound guided long axis radial artery cannulation in patients over 60 years old: a randomized study
Q92495927Modified long-axis in-plane ultrasound technique versus conventional palpation technique for radial arterial cannulation: A prospective randomized controlled trial
Q47683895Nerve blocks or no nerve blocks for pain control after elective hip replacement (arthroplasty) surgery in adults.
Q35105633Optimal site for ultrasound-guided venous catheterisation in paediatric patients: an observational study to investigate predictors for catheterisation success and a randomised controlled study to determine the most successful site
Q36302380Spectral tissue sensing to identify intra- and extravascular needle placement - A randomized single-blind controlled trial
Q46204895The advanced radial artery cannulation using Insyte-A™ with real-time ultrasound guidance
Q38459969The effect of electromagnetic guidance system on early learning curve of ultrasound for novices.
Q39616598Ultrasonic Technology Improves Radial Artery Puncture and Cannulation in Intensive Care Unit (ICU) Shock Patients
Q58570181Ultrasonography and Seldinger's technique: Using the best of both worlds for difficult radial artery cannulation!
Q40899526Ultrasound evaluation of the radial artery for arterial catheterization in healthy anesthetized patients
Q34465896Ultrasound guidance for radial artery catheterization: an updated meta-analysis of randomized controlled trials
Q90348177Ultrasound-Guided Artery Cannulation Technique Versus Palpation Technique in Adult Patients in Pre-Anesthesia Room: A Randomized Controlled Trial

Search more.