A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care.

scientific article published on 31 January 2018

A technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1007/S10877-017-0097-9
P932PMC publication ID6061082
P698PubMed publication ID29388094

P50authorGlen OomenQ87661780
P2093author name stringPauric Carey
Ron Farrell
P2860cites workVolatile sedation with sevoflurane in intensive care patients with acute stroke or subarachnoid haemorrhage using AnaConDa®: an observational studyQ35590450
Isoflurane compared with midazolam for sedation in the intensive care unitQ35711931
Inhalational anaesthetics in the ICU: theory and practice of inhalational sedation in the ICU, economics, risk-benefitQ36192585
State of the art: sedation concepts with volatile anesthetics in critically Ill patientsQ37425534
Volatile Anesthetics. Is a New Player Emerging in Critical Care Sedation?Q38784583
Technical performance and reflection capacity of the anaesthetic conserving device--a bench study with isoflurane and sevofluraneQ42063486
A new device to reduce the consumption of a halogenated anaesthetic agentQ43605767
The sevoflurane saving capacity of a new anaesthetic agent conserving device compared with a low flow circle systemQ44004352
The anesthetic conserving device compared with conventional circle system used under different flow conditions for inhaled anesthesiaQ44372024
Prolonged isoflurane sedation of intensive care unit patients with the Anesthetic Conserving DeviceQ45217239
Ambient isoflurane pollution and isoflurane consumption during intensive care unit sedation with the Anesthetic Conserving DeviceQ45309312
The scavenging of volatile anesthetic agents in the cardiovascular intensive care unit environment: a technical report.Q46057084
Short-term evaluation of sedation with sevoflurane administered by the anesthetic conserving device in critically ill patientsQ46135628
Feasibility and potential cost/benefit of routine isoflurane sedation using an anesthetic-conserving device: a prospective observational study.Q46351180
Short-term sevoflurane sedation using the Anaesthetic Conserving Device after cardiothoracic surgeryQ46578374
The predictive performance of a pharmacokinetic model for manually adjusted infusion of liquid sevofluorane for use with the Anesthetic-Conserving Device (AnaConDa): a clinical studyQ46694818
Three cases of PICU sedation with isoflurane delivered by the 'AnaConDa'.Q46714564
Impact of the anesthetic conserving device on respiratory parameters and work of breathing in critically ill patients under light sedation with sevoflurane.Q47831490
Anaesthetic conserving device AnaConDa: dead space effect and significance for lung protective ventilationQ47865141
Health worker exposure risk during inhalation sedation with sevoflurane using the (AnaConDa®) anaesthetic conserving deviceQ47923256
Apparent dead space with the anesthetic conserving device, AnaConDa®: a clinical and laboratory investigationQ47947243
Volatile isoflurane sedation in cerebrovascular intensive care patients using AnaConDa®: effects on cerebral oxygenation, circulation, and pressureQ48120718
Surpassing boundaries: volatile sedation in the NeuroICU.Q48124570
Current certainties and future developments in the use of the anaesthetic conserving device (AnaConDa)Q48184500
Flow resistance, work of breathing of humidifiers, and endotracheal tubes in the hyperbaric chamberQ85000301
P275copyright licenseCreative Commons Attribution 4.0 InternationalQ20007257
P6216copyright statuscopyrightedQ50423863
P433issue4
P921main subjectvolatile anaestheticQ126282515
P304page(s)595-604
P577publication date2018-01-31
P1433published inJournal of Clinical Monitoring and ComputingQ5310493
P1476titleA technical review of the history, development and performance of the anaesthetic conserving device "AnaConDa" for delivering volatile anaesthetic in intensive and post-operative critical care
P478volume32

Reverse relations

cites work (P2860)
Q94452536Advances in vaporisation: A narrative review
Q64053711Does volatile sedation with sevoflurane allow spontaneous breathing during prolonged prone positioning in intubated ARDS patients? A retrospective observational feasibility trial
Q89122090Sedation with inhaled agents in the ICU: what are we waiting for?

Search more.