Three-dimensional T2-weighted imaging for liver MRI: clinical values of tissue-specific variable refocusing flip-angle turbo spin echo imaging

scientific article published on 8 January 2014

Three-dimensional T2-weighted imaging for liver MRI: clinical values of tissue-specific variable refocusing flip-angle turbo spin echo imaging is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1002/JMRI.24554
P698PubMed publication ID24399511

P50authorYukihisa TakayamaQ114440705
Atsushi TakemuraQ88110049
Takashi YoshiuraQ88110055
Yoshiki AsayamaQ88575700
Masami YoneyamaQ88632966
H HondaQ88632968
Makoto ObaraQ89581259
Akihiro NishieQ89914901
Nobuhiro FujitaQ91958797
Yasuhiro UshijimaQ102145028
P2093author name stringDai Shimamoto
P2860cites workManagement of hepatocellular carcinomaQ29616230
Optimized single-slab three-dimensional spin-echo MR imaging of the brainQ30306018
Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosisQ33694318
Carotid arterial wall MRI at 3T using 3D variable-flip-angle turbo spin-echo (TSE) with flow-sensitive dephasing (FSD).Q33737407
Focal nodular hyperplasia: findings at state-of-the-art MR imaging, US, CT, and pathologic analysisQ35632208
Focal liver lesion detection and characterization with diffusion-weighted MR imaging: comparison with standard breath-hold T2-weighted imagingQ37068523
N/2 ghosting artifacts: elimination at 3.0-T MR cholangiography with SPACE pulse sequenceQ37070054
MR imaging of hypervascular liver masses: a review of current techniquesQ37424601
Uterine tumors: comparison of 3D versus 2D T2-weighted turbo spin-echo MR imaging at 3.0 T--initial experienceQ37806462
Peripheral low intensity sign in hepatic hemangioma: diagnostic pitfall in hepatobiliary phase of Gd-EOB-DTPA-enhanced MRI of the liverQ37962879
Effects of refocusing flip angle modulation and view ordering in 3D fast spin echoQ42582141
Effect of Gd-EOB-DTPA on T2-weighted and diffusion-weighted images for the diagnosis of hepatocellular carcinomaQ43005776
Reduced RF power without blurring: correcting for modulation of refocusing flip angle in FSE sequencesQ46713974
Contrast-enhanced, three-dimensional, whole-brain, black-blood imaging: application to small brain metastasesQ48291858
Image quality of Gd-EOB-DTPA-enhanced magnetic resonance imaging of the liver using dual-source parallel radiofrequency transmission technology: Comparison with the post-processing correction method for B1 inhomogeneity-induced signal lossQ49149700
Quantitative and qualitative comparison of 3.0T and 1.5T MR imaging of the liver in patients with diffuse parenchymal liver disease.Q50232026
Fast spin echo sequences with very long echo trains: design of variable refocusing flip angle schedules and generation of clinical T2 contrast.Q51232350
Prostate cancer: Comparison of 3D T2-weighted with conventional 2D T2-weighted imaging for image quality and tumor detection.Q51727308
Magnetic resonance imaging of the body trunk using a single-slab, 3-dimensional, T2-weighted turbo-spin-echo sequence with high sampling efficiency (SPACE) for high spatial resolution imaging: initial clinical experiences.Q51959550
T2-weighted and diffusion-weighted MRI for discriminating benign from malignant focal liver lesions: diagnostic abilities of single versus combined interpretations.Q53094240
Evaluation of uterine anomalies: 3D FRFSE cube versus standard 2D FRFSE.Q53322977
High spatial resolution 3D MR cholangiography with high sampling efficiency technique (SPACE): comparison of 3T vs. 1.5T.Q53392051
Multiecho sequences with variable refocusing flip angles: optimization of signal behavior using smooth transitions between pseudo steady states (TRAPS).Q53658422
MRI of the pelvis at 3 T: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan timeQ58870064
Altered carotid plaque signal among different repetition times on T1-weighted magnetic resonance plaque imaging with self-navigated radial-scan techniqueQ59113826
P433issue2
P304page(s)339-346
P577publication date2014-01-08
P1433published inJournal of Magnetic Resonance ImagingQ15761156
P1476titleThree-dimensional T2-weighted imaging for liver MRI: clinical values of tissue-specific variable refocusing flip-angle turbo spin echo imaging
P478volume41