Less invasive reduction and fusion of fresh A2 and A 3 traumatic L 1-L 4 fractures with a novel vertebral body augmentation implant and short pedicle screw fixation and fusion

scientific article published on 30 October 2013

Less invasive reduction and fusion of fresh A2 and A 3 traumatic L 1-L 4 fractures with a novel vertebral body augmentation implant and short pedicle screw fixation and fusion is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1007/S00590-013-1339-2
P698PubMed publication ID24170266
P5875ResearchGate publication ID258147924

P2093author name stringKonstantinos Vardakastanis
Panagiotis Korovessis
Vasilios Vitsas
Thomas Repantis
P2860cites workBalloon kyphoplasty and vertebroplasty for vertebral compression fractures: a comparative systematic review of efficacy and safetyQ28271447
Initial clinical experience with a novel vertebral augmentation system for treatment of symptomatic vertebral compression fractures: a case series of 26 consecutive patientsQ34027886
International standards for neurological classification of spinal cord injuryQ34468648
Transpedicle body augmenter in painful osteoporotic compression fracturesQ36404707
Short-segment fixation of lumbar burst fractures using pedicle fixation at the level of the fracture.Q36850736
Acute respiratory distress syndrome associated with pulmonary cement embolism following percutaneous vertebroplasty with polymethylmethacrylateQ40530110
The load sharing classification of spine fractures.Q42594974
Combined anterior plus posterior stabilization versus posterior short-segment instrumentation and fusion for mid-lumbar (L2-L4) burst fracturesQ42683448
Serious pyogenic spondylitis following vertebroplasty--a case reportQ44882130
Minimal invasive short posterior instrumentation plus balloon kyphoplasty with calcium phosphate for burst and severe compression lumbar fracturesQ45755985
Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report.Q45944567
Unstable thoracolumbar and lumbar burst fractures treated with the AO fixateur interneQ46349720
Vertebral body stenting versus kyphoplasty for the treatment of osteoporotic vertebral compression fractures: a randomized trial.Q46920474
Kyphosis recurrence after posterior short-segment fixation in thoracolumbar burst fracturesQ47876866
Balloon kyphoplasty versus KIVA vertebral augmentation--comparison of 2 techniques for osteoporotic vertebral body fractures: a prospective randomized study.Q50723336
The treatment of acute thoracolumbar burst fractures with transpedicular intracorporeal hydroxyapatite grafting following indirect reduction and pedicle screw fixation: a prospective study.Q51235600
Bone displacement and the role of longitudinal ligaments during balloon vertebroplasty in traumatic thoracolumbar fractures.Q51371059
Balloon vertebroplasty in combination with pedicle screw instrumentation: a novel technique to treat thoracic and lumbar burst fractures.Q51546813
Percutaneous placement of pedicle screws in overweight and obese patients.Q51854623
Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): a randomised controlled trial.Q53113377
Short-Segment Pedicle Instrumentation of Thoracolumbar Burst FracturesQ58461515
Interobserver and Intraobserver Agreement of Radiograph Interpretation With and Without Pedicle Screw ImplantsQ60439799
Theoretical and experimental model to describe the injection of a polymethylmethacrylate cement into a porous structureQ61827166
Transpedicular fixation of thoracolumbar vertebral fracturesQ68256264
Spinal mobility and deformity after Harrington rod stabilization and limited arthrodesis of thoracolumbar fracturesQ70536374
Transpedicular instrumentation and short-segment fusion of thoracolumbar fractures: a prospective study using a single instrumentation systemQ70979424
Back pain after thoracolumbar fracture treated with long instrumentation and short fusionQ71010731
A lethal pulmonary embolism during percutaneous vertebroplastyQ78290238
Pulmonary embolism of polymethyl methacrylate during percutaneous vertebroplasty and kyphoplastyQ80600617
Cement leakage as a possible complication of balloon kyphoplasty--is there a difference between osteoporotic compression fractures (AO type A1) and incomplete burst fractures (AO type A3.1)?Q82833989
Thoracolumbar burst fractures treated with posterior decompression and pedicle screw instrumentation supplemented with balloon-assisted vertebroplasty and calcium phosphate reconstructionQ83144076
Posterior short-segment fixation with or without fusion for thoracolumbar burst fractures. a five to seven-year prospective randomized studyQ83762538
P433issue3
P304page(s)297-304
P577publication date2013-10-30
P1433published inEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologieQ27723812
P1476titleLess invasive reduction and fusion of fresh A2 and A 3 traumatic L 1-L 4 fractures with a novel vertebral body augmentation implant and short pedicle screw fixation and fusion
P478volume24

Reverse relations

cites work (P2860)
Q89612384Clinical, radiological, and patient-reported outcomes 13 years after pedicle screw fixation with balloon-assisted endplate reduction and cement injection
Q39348533Requirements for a Stable Long-Term Result in Surgical Reduction of Vertebral Fragility Fractures

Search more.