Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients.

scientific article published on 9 November 2006

Efficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1007/S00296-006-0256-7
P698PubMed publication ID17094002

P50authorMasashi NeoQ46738090
P2093author name stringT Nakamura
M Yoshida
H Ito
H Yoshitomi
S Fujibayashi
P2860cites workThe american rheumatism association 1987 revised criteria for the classification of rheumatoid arthritisQ27860872
Natural history of rheumatoid arthritis of the cervical spine.Q33812539
Incidence of noncardiac vascular disease in rheumatoid arthritis and relationship to extraarticular disease manifestationsQ34712199
Rheumatoid arthritis: evaluation and surgical management of the cervical spineQ35947859
Rheumatoid arthritis: a disease associated with accelerated atherogenesisQ36220303
Rheumatoid arthritis and vertebral artery occlusion: a case report with angiographic and magnetic resonance demonstration.Q41072213
Complications of transpedicular screw fixation in the cervical spineQ41487269
Prognosis of patients with upper cervical lesions caused by rheumatoid arthritis: comparison of occipitocervical fusion between c1 laminectomy and nonsurgical managementQ47756446
The clinical risk of vertebral artery injury from cervical pedicle screws inserted in degenerative vertebrae.Q51300276
Cervical pedicle screws: conventional versus computer-assisted placement of cannulated screws.Q51338508
Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle.Q51581797
Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine.Q51584170
Improved accuracy of computer-assisted cervical pedicle screw insertionQ51811345
Cervical spine fusion in rheumatoid arthritisQ66943336
A prospective study of the progression of rheumatoid arthritis of the cervical spineQ70687259
Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spineQ72544594
Atlantoaxial arthrodesis for vertebrobasilar insufficiency due to rheumatoid arthritis: a case reportQ73208964
Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparisonQ73341941
Pedicle screw fixation for nontraumatic lesions of the cervical spineQ73655109
Complications of pedicle screw fixation in reconstructive surgery of the cervical spineQ73682811
Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidanceQ73936855
Relative contribution of cardiovascular risk factors and rheumatoid arthritis clinical manifestations to atherosclerosisQ81412936
P433issue6
P304page(s)567-574
P577publication date2006-11-09
P1433published inRheumatology InternationalQ15763689
P1476titleEfficacy of computer-assisted pedicle screw insertion for cervical instability in RA patients.
P478volume27

Reverse relations

cites work (P2860)
Q916484613D-Customized Guiding Template for Posterior Fixation in Complex Atlantoaxial Instability-Preliminary Experiences of National Cheng Kung University Hospital
Q400570703D-based navigation in posterior stabilisations of the cervical and thoracic spine: problems and benefits. Results of 451 screws
Q85889955A statistical shape model of the human second cervical vertebra
Q42257918Advantages and Disadvantages of Multi-axis Intraoperative Angiography Unit for Percutaneous Pedicle Screw Placement in the Lumbar Spine
Q33973296Anterior cervical pedicle screw and plate fixation using fluoroscope-assisted pedicle axis view imaging: a preliminary report of a new cervical reconstruction technique
Q35069496CT morphometric analysis to determine the anatomical basis for the use of transpedicular screws during reconstruction and fixations of anterior cervical vertebrae
Q36542594Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.
Q36542590Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites
Q36490080Cervical pedicle screw fixation combined with laminoplasty for cervical spondylotic myelopathy with instability
Q33972803Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve
Q38815633Differences between Manufacturers of Computed Tomography-Based Computer-Assisted Surgery Systems Do Exist: A Systematic Literature Review
Q37669250Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws
Q42197938Image-guided pedicle screw insertion accuracy: a meta-analysis
Q37599578Image-guided spine surgery: state of the art and future directions
Q33972843In vitro study of accuracy of cervical pedicle screw insertion using an electronic conductivity device (ATPS part III).
Q53534505Morphological and clinical feasibility of C3 pedicle screw instrumentation in patients with congenital C2-3 fusion.
Q38870894Navigation and Robotics in Spinal Surgery: Where Are We Now?
Q34996278Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies
Q33829267Perforation rates of cervical pedicle screw insertion by disease and vertebral level.
Q36905349Screw Placement Accuracy and Outcomes Following O-Arm-Navigated Atlantoaxial Fusion: A Feasibility Study
Q51079572The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.
Q36973233The correlation between cervical range of motion and misplacement of cervical pedicle screws during cervical posterior spinal fixation surgery using a CT-based navigation system
Q38493286The evolution of image-guided lumbosacral spine surgery