Detection of ground-glass opacities by use of hybrid iterative reconstruction (iDose) and low-dose 256-section computed tomography: a phantom study.

scientific article published on 12 February 2013

Detection of ground-glass opacities by use of hybrid iterative reconstruction (iDose) and low-dose 256-section computed tomography: a phantom study. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1007/S12194-013-0200-Y
P698PubMed publication ID23400447
P5875ResearchGate publication ID235522728

P50authorH HondaQ88632968
Michinobu NagaoQ114440700
P2093author name stringYoshio Matsuo
Hidetake Yabuuchi
Masato Yonezawa
Takeshi Kamitani
Ko Higuchi
Yuzo Yamasaki
Shunya Sunami
Mikako Jinnouchi
Masamitsu Hatkenaka
P2860cites workComputed Tomography — An Increasing Source of Radiation ExposureQ22121933
Cancer risks from diagnostic radiologyQ22241582
Reduced lung-cancer mortality with low-dose computed tomographic screeningQ28241954
OsiriX: an open-source software for navigating in multidimensional DICOM imagesQ31126270
A consensus statement of the Society of Thoracic Radiology: screening for lung cancer with helical computed tomographyQ34125794
State of the art: technologies for computed tomography dose reductionQ35014437
Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiographyQ35150456
Adult patient radiation doses from non-cardiac CT examinations: a review of published resultsQ36323989
Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults.Q37427187
Iterative reconstruction for coronary CT angiography: finding its way.Q37848166
Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomographyQ44453901
The development and use of a chest phantom for optimizing scanning techniques on a variety of low-dose helical computed tomography devicesQ44470483
Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: experimental study using chest phantomQ45827929
Computed tomography--old ideas and new technology.Q47327430
Lung cancers missed at low-dose helical CT screening in a general population: comparison of clinical, histopathologic, and imaging findings.Q50711292
Initial performance characterization of a clinical noise-suppressing reconstruction algorithm for MDCT.Q51491560
Detection of nodules showing ground-glass opacity in the lungs at low-dose multidetector computed tomography: phantom and clinical study.Q51853160
Measurement of localized ground-glass attenuation on thin-section computed tomography images: correlation with the progression of bronchioloalveolar carcinoma of the lung.Q53665904
P433issue2
P921main subjectground glass opacityQ3150728
P1104number of pages6
P304page(s)299-304
P577publication date2013-02-12
P1433published inRadiological physics and technologyQ27722838
P1476titleDetection of ground-glass opacities by use of hybrid iterative reconstruction (iDose) and low-dose 256-section computed tomography: a phantom study.
P478volume6

Reverse relations

cites work (P2860)
Q35676672Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study
Q34083796Adaptive Iterative Dose Reduction Using Three Dimensional Processing (AIDR3D) improves chest CT image quality and reduces radiation exposure
Q36550937Low-dose CT screening using hybrid iterative reconstruction: confidence ratings of diagnoses of simulated lesions other than lung cancer
Q47558364Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels: A Phantom Study in Chest CT.