scholarly article | Q13442814 |
P2093 | author name string | Pandit JJ | |
Dravid RM | |||
MacLachlan K | |||
Popat MT | |||
P2860 | cites work | Laryngeal mask and fibreoptic tracheal intubation. | Q51632969 |
A clinical sign to predict difficult tracheal intubation: a prospective study | Q28235648 | ||
Difficult tracheal intubation: a retrospective study | Q28301212 | ||
The 'dedicated airway': a review of the concept and an update of current practice | Q33719080 | ||
Difficult tracheal intubation in obstetrics | Q34262564 | ||
Cricoid pressure impedes placement of the laryngeal mask airway | Q39230214 | ||
Laryngeal mask airway and the ASA difficult airway algorithm | Q41003651 | ||
Intubating laryngeal mask and rapid sequence induction in patients with cervical spine injury | Q42050948 | ||
Cricoid pressure may prevent insertion of the laryngeal mask airway | Q43871556 | ||
Sixteen S-squared over D-squared: a relation for crude sample size estimates | Q47410829 | ||
The intubating laryngeal mask. II: A preliminary clinical report of a new means of intubating the trachea | Q48515830 | ||
The intubating laryngeal mask. I: Development of a new device for intubation of the trachea | Q48515841 | ||
A manoeuvre for using the flexible fibreoptic bronchoscope through the Intubating Laryngeal Mask Airway. | Q51353386 | ||
A comparison of blind and lightwand-guided tracheal intubation through the intubating laryngeal mask. | Q51404095 | ||
A comparison of the intubating laryngeal mask tracheal tube with a standard tracheal tube for fibreoptic intubation. | Q51405776 | ||
Large goitre causing difficult intubation and failure to intubate using the intubating laryngeal mask airway: lessons for next time. | Q51463330 | ||
The intubating laryngeal mask. Results of a multicentre trial with experience of 500 cases. | Q51467177 | ||
The intubating laryngeal mask. Use in failed and difficult intubation. | Q51517914 | ||
P433 | issue | 2 | |
P407 | language of work or name | English | Q1860 |
P921 | main subject | larynx | Q9637 |
P304 | page(s) | 128-132 | |
P577 | publication date | 2002-02-01 | |
P1433 | published in | Anaesthesia | Q59768 |
P1476 | title | Comparison of times to achieve tracheal intubation with three techniques using the laryngeal or intubating laryngeal mask airway. | |
P478 | volume | 57 |
Q47364074 | A cadaver study comparing three fibreoptic-assisted techniques for converting a supraglottic airway to a cuffed tracheal tube. |
Q33626381 | A comparison of conventional endotracheal tube with silicone wire-reinforced tracheal tube for intubation through intubating laryngeal mask airway |
Q47755720 | A comparison of fibreoptic-guided tracheal intubation through the Ambu ® Aura-i ™, the intubating laryngeal mask airway and the i-gel ™: a manikin study |
Q48702362 | Awake intubation through the CTrach in the presence of an unstable cervical spine. |
Q48286836 | Comparison of blind tracheal intubation through the intubating laryngeal mask airway (LMA Fastrach™) and the Air-Q™. |
Q48805992 | Comparison of fibreoptic-guided orotracheal intubation through classic and single-use laryngeal mask airways |
Q99551417 | Comparison of glottic visualisation through supraglottic airway device (SAD) using bronchoscope in the ramped versus supine 'sniffing air' position: A pilot feasibility study |
Q58788190 | Comparison of the Success Rate of Intubation Between the LMA Fastrach and AirQ-ILA Methods in Patients Undergoing Elective Surgery During General Anaesthesia |
Q36294529 | Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults |
Q47968046 | Difficult Airway Society guidelines for management of the unanticipated difficult intubation |
Q55262093 | Direct and indirect low skill fibre-optic intubation: A randomised crossover manikin study of six supraglottic airway devices. |
Q47910209 | Endotracheal intubation with intubating laryngeal mask airway (ILMA), C-Trach, and Cobra PLA in simulated cervical spine injury patients: a comparative study |
Q48408969 | Fibreoptic intubation through the laryngeal mask airway: effect of operator experience*. |
Q49351800 | I-Gel versus laryngeal mask airway (LMA) classic as a conduit for tracheal intubation using ventilating bougie |
Q34934798 | Lingual ischemia from prolonged insertion of a fastrach laryngeal mask airway |
Q48793350 | Low-skill fibreoptic intubation: use of the Aintree Catheter with the classic LMA. |
Q47981179 | Paramedic tracheal intubation using the intubating laryngeal mask airway |
Q58612015 | Supraglottic airway devices as a strategy for unassisted tracheal intubation: A network meta-analysis |
Q35980503 | The air-Q(®) intubating laryngeal airway vs the LMA-ProSeal(TM) : a prospective, randomised trial of airway seal pressure |
Q47613809 | Time to abandon awake fibreoptic intubation? |
Q48188479 | Tracheal intubation in morbidly obese patients: a comparison of the Intubating Laryngeal Mask Airway™ and Laryngeal Mask Airway CTrach™. |
Q49962331 | Tracheal intubation through laryngeal mask airway CTrach™ with polyvinyl chloride tube: Comparison between two orientations of the tracheal tube |
Q48687442 | Tracheal intubation using the ILMA, C-Trach or McCoy laryngoscope in patients with simulated cervical spine injury |
Q48118768 | Tracheal intubation with a camera embedded in the tube tip (Vivasight(™) ). |
Q48027466 | Tracheal intubation with a camera embedded in the tube tip. |
Q48961823 | Use of the bougie in simulated difficult intubation. 1. Comparison of the single-use bougie with the fibrescope |
Q42619272 | Value of knowing physical characteristics of the airway device before using it. |
Search more.