Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system

scientific article published on October 1, 2003

Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1118/1.1593637
P953full work available at URLhttps://api.wiley.com/onlinelibrary/tdm/v1/articles/10.1118%2F1.1593637
https://onlinelibrary.wiley.com/doi/full/10.1118/1.1593637
P698PubMed publication ID14596302

P50authorChristoph SüßQ103831371
P2093author name stringJ. Simon
Th Flohr
C. Suess
B. Ohnesorge
S. Schaller
K. Stierstorfer
H. Bruder
P2860cites workNoninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.Q33181497
Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstructionQ33186018
Multi-slice helical CT: scan and reconstructionQ38547507
Noninvasive detection and evaluation of atherosclerotic coronary plaques with multislice computed tomographyQ40713706
High temporal resolution for multislice helical computed tomographyQ45430520
Image reconstruction and image quality evaluation for a 16-slice CT scannerQ46981280
ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart.Q50776578
Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Q51701061
Spiral interpolation algorithm for multislice spiral CT--part I: theory.Q52069889
Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience.Q52071990
Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.Q52228265
Algorithm for image reconstruction in multi-slice helical CT.Q52244095
New technical developments in multislice CT--Part 1: Approaching isotropic resolution with sub-millimeter 16-slice scanning.Q53676604
Some windows with very good sidelobe behaviorQ56209747
Noninvasive detection of coronary artery stenosis by multislice helical computed tomographyQ73889123
Imaging of noncalcified coronary plaques using helical CT with retrospective ECG gatingQ74071119
ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image qualityQ74433450
Coronary angiography with multi-slice computed tomographyQ74517268
Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction windowQ77221275
P433issue10
P407language of work or nameEnglishQ1860
P1104number of pages13
P304page(s)2650-2662
P577publication date2003-10-01
P1433published inMedical PhysicsQ15764251
P1476titleImage reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system
P478volume30

Reverse relations

cites work (P2860)
Q50783058Age related changes of human aortic distensibility: evaluation with ECG-gated CT.
Q51980250Automatic phase determination for retrospectively gated cardiac CT.
Q38774800Detectability of motions in AAA with ECG-gated CTA: A quantitative study
Q51946329Direct cone-beam cardiac reconstruction algorithm with cardiac banding artifact correction.
Q45000010Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom
Q41826742Image reconstruction and image quality evaluation for a dual source CT scanner
Q33201148Imaging of coronary atherosclerosis using computed tomography: current status and future directions
Q57158442Impact of a novel exponential weighted 4DCT reconstruction algorithm
Q37285468Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
Q53388943Integrated assessment of coronary anatomy and myocardial perfusion using a retractable SPECT camera combined with 64-slice CT: initial experience.
Q45352983Multithreaded cardiac CT.
Q31126270OsiriX: an open-source software for navigating in multidimensional DICOM images
Q31033659Phase versus amplitude sorting of 4D-CT data
Q51389634Quantification of aortic elasticity: development and experimental validation of a method using computed tomography.
Q55027173Radiation dose and physical image quality in 128-section dual-source computed tomographic coronary angiography: a phantom study.
Q47664447Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation
Q47796177Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation
Q31083441Step-and-shoot data acquisition and reconstruction for cardiac x-ray computed tomography
Q42410852The Role of Multidetector CT in the Diagnosis of Retroperitoneal Fibrosis: Report of a Case

Search more.