4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy.

scientific article published in December 2007

4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1118/1.2804722
P698PubMed publication ID18196820

P2093author name stringLech Papiez
Robert Timmerman
Ryan McMahon
P2860cites workOrgan motion and its managementQ33943656
Motion effects in (intensity modulated) radiation therapy: a reviewQ36514659
Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulationQ38487999
Inverse planning incorporating organ motionQ41756280
Motion adaptive x-ray therapy: a feasibility studyQ44879491
The management of respiratory motion in radiation oncology report of AAPM Task Group 76.Q44924583
Temporo-spatial IMRT optimization: concepts, implementation and initial resultsQ47787456
A stochastic convolution/superposition method with isocenter sampling to evaluate intrafraction motion effects in IMRT.Q47796165
The effect on IMRT conformality of elastic tissue movement and a practical suggestion for movement compensation via the modified dynamic multileaf collimator (dMLC) technique.Q47823868
Effects of motion on the total dose distributionQ48025012
DMLC leaf-pair optimal control for mobile, deforming target.Q51538932
A method for incorporating organ motion due to breathing into 3D dose calculations in the liver: sensitivity to variations in motion.Q51645796
Real-time DMLC IMRT delivery for mobile and deforming targets.Q51960774
DMLC leaf-pair optimal control of IMRT delivery for a moving rigid target.Q51984259
P433issue12
P407language of work or nameEnglishQ1860
P304page(s)4952-4956
P577publication date2007-12-01
P1433published inMedical PhysicsQ15764251
P1476title4D DMLC leaf sequencing to minimize organ at risk dose in moving anatomy.
P478volume34

Reverse relations

cites work (P2860)
Q46326464A real-time dynamic-MLC control algorithm for delivering IMRT to targets undergoing 2D rigid motion in the beam's eye view
Q36805626Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer.
Q36218279Four-dimensional dose distributions of step-and-shoot IMRT delivered with real-time tumor tracking for patients with irregular breathing: constant dose rate vs dose rate regulation
Q40353134Four-dimensional planning for motion synchronized dose delivery in lung stereotactic body radiation therapy
Q51802326General strategy for the protection of organs at risk in IMRT therapy of a moving body.
Q39541006Inverse 4D conformal planning for lung SBRT using particle swarm optimization
Q42365700Magnitude, Impact, and Management of Respiration-induced Target Motion in Radiotherapy Treatment: A Comprehensive Review
Q47384096The development of a 4D treatment planning methodology to simulate the tracking of central lung tumors in an MRI-linac
Q42965184Use of dMLC for implementation of dynamic respiratory-gated radiation therapy
Q51860498Variable beam dose rate and DMLC IMRT to moving body anatomy.

Search more.