Intra- and interoperator reproducibility of acoustic radiation force impulse (ARFI) elastography--preliminary results.

scientific article

Intra- and interoperator reproducibility of acoustic radiation force impulse (ARFI) elastography--preliminary results. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1016/J.ULTRASMEDBIO.2012.02.032
P698PubMed publication ID22579536

P50authorRoxana SirliQ51127460
P2093author name stringAlina Popescu
Ioan Sporea
Mirela Danila
Simona Bota
Dan Costachescu
P2860cites workSerum markers detect the presence of liver fibrosis: a cohort study.Q51983072
Accuracy of VirtualTouch Acoustic Radiation Force Impulse (ARFI) imaging for the diagnosis of cirrhosis during liver ultrasonography.Q53080614
Assessment of Liver Fibrosis and Steatosis in PBC With FibroScan, MRI, MR-spectroscopy, and Serum MarkersQ58622658
The role of liver biopsy in chronic hepatitis CQ61698877
Real-time elastography for noninvasive assessment of liver fibrosis in chronic viral hepatitisQ79803212
Liver biopsy in cirrhotic patientsQ79835016
Transient elastography predicts fibrosis progression in patients with recurrent hepatitis C after liver transplantationQ80546480
Liver biopsyQ83395480
Reproducibility of shear wave velocity measurements by acoustic radiation force impulse imaging of the liver: a study in healthy volunteersQ84447834
Acoustic radiation force impulse elastography as compared to transient elastography and liver biopsy in patients with chronic hepatopathiesQ84527076
Evaluation of liver fibrosis by transient elastography using acoustic radiation force impulse: comparison with Fibroscan(®)Q84584125
Evaluation of acoustic radiation force impulse elastography for fibrosis staging of chronic liver disease: a pilot studyQ84814912
Robust principal component analysis and clustering methods for automated classification of tissue response to ARFI excitationQ30444658
Is it better to use two elastographic methods for liver fibrosis assessment?Q30473767
Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis.Q30484815
An integrated indenter-ARFI imaging system for tissue stiffness quantification.Q30492833
Elastography for the diagnosis of severity of fibrosis in chronic liver disease: a meta-analysis of diagnostic accuracyQ33767530
The management of ascites in cirrhosis: report on the consensus conference of the International Ascites ClubQ33966809
Prospective comparison of transient elastography, Fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C.Q34390093
Reproducibility of transient elastography in the evaluation of liver fibrosis in patients with chronic liver diseaseQ36014015
The role of liver biopsy in hepatitis C.Q41598789
Comparison of transient elastography and acoustic radiation force impulse for non-invasive staging of liver fibrosis in patients with chronic hepatitis C.Q43041031
Direct comparison of diagnostic performance of transient elastography in patients with chronic hepatitis B and chronic hepatitis C.Q44707599
Acoustic radiation force impulse: a new ultrasonographic technology for the widespread noninvasive diagnosis of liver fibrosisQ44805217
Liver fibrosis in viral hepatitis: noninvasive assessment with acoustic radiation force impulse imaging versus transient elastographyQ45055754
Noninvasive in vivo liver fibrosis evaluation using supersonic shear imaging: a clinical study on 113 hepatitis C virus patients.Q45364849
Biochemical markers of liver fibrosis in patients infected by hepatitis C virus: longitudinal validation in a randomized trialQ45733502
Noninvasive evaluation of hepatic fibrosis using serum fibrotic markers, transient elastography (FibroScan) and real-time tissue elastographyQ46547124
Freehand real-time elastography: impact of scanning parameters on image quality and in vitro intra- and interobserver validationsQ47663442
What did we learn from the first 3,459 cases of liver stiffness measurement by transient elastography (FibroScan®)?Q51682528
P433issue7
P921main subjectreproducibilityQ1425625
P304page(s)1103-1108
P577publication date2012-05-12
P1433published inUltrasound in Medicine and BiologyQ2260380
P1476titleIntra- and interoperator reproducibility of acoustic radiation force impulse (ARFI) elastography--preliminary results.
P478volume38

Reverse relations

cites work (P2860)
Q90700183A New Multimodel Machine Learning Framework to Improve Hepatic Fibrosis Grading Using Ultrasound Elastography Systems from Different Vendors
Q30382849Acoustic radiation force impulse imaging for assessing liver fibrosis in alcoholic liver disease.
Q58011435Assessing liver function by liver enhancement during the hepatobiliary phase with Gd-EOB-DTPA-enhanced MRI at 3 Tesla
Q38791953Assessment of Measurement Repeatability and Reliability With Virtual Touch Tissue Quantification Imaging in Cervical Lymphadenopathy
Q30444857Assessment of clinical signs of liver cirrhosis using T1 mapping on Gd-EOB-DTPA-enhanced 3T MRI
Q48234623Clinical strategy of diagnosing and following patients with nonalcoholic fatty liver disease based on invasive and noninvasive methods.
Q38858344Critical comparison of elastography methods to assess chronic liver disease
Q30405470Cross-vendor validation of liver magnetic resonance elastography
Q92190130Cutoff Values of Acoustic Radiation Force Impulse Two-Location Measurements in Different Etiologies of Liver Fibrosis
Q55028445DWI - histology: a possible means of determining degree of liver fibrosis?
Q59793497Diagnostic performance of Gd-EOB-DTPA-enhanced MRI for evaluation of liver dysfunction: a multivariable analysis of 3T MRI sequences
Q51287827Factors which influence the accuracy of acoustic radiation force impulse (ARFI) elastography for the diagnosis of liver fibrosis in patients with chronic hepatitis C.
Q51397839Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.
Q64989839Influence of hepatic fibrosis and inflammation: Correlation between histopathological changes and Gd-EOB-DTPA-enhanced MR imaging.
Q56542428Inter-sonographer reproducibility of quantitative ultrasound outcomes and shear wave speed measured in the right lobe of the liver in adults with known or suspected non-alcoholic fatty liver disease
Q88866256Intra- and Inter-Observer Reproducibility of a 2-D Shear Wave Elastography Technique and the Impact of Ultrasound Experience in Achieving Reliable Data
Q92027344Intra- and inter-operator reproducibility of US point shear-wave elastography in various organs: evaluation in phantoms and healthy volunteers
Q30423495Kidney shear wave speed values in subjects with and without renal pathology and inter-operator reproducibility of acoustic radiation force impulse elastography (ARFI)--preliminary results
Q53219609Liver and Spleen Stiffness Measurements by Point Shear Wave Elastography via Acoustic Radiation Force Impulse: Intraobserver and Interobserver Variability and Predictors of Variability in a US Population.
Q100395106Liver and spleen elastography of dogs affected by brachycephalic obstructive airway syndrome and its correlation with clinical biomarkers
Q30359290Liver fibrosis and Gd-EOB-DTPA-enhanced MRI: A histopathologic correlation
Q30421450Non invasive tools for the diagnosis of liver cirrhosis.
Q26744631Non-invasive Markers of Liver Fibrosis: Adjuncts or Alternatives to Liver Biopsy?
Q38588078Non-invasive assessment of liver fibrosis and prognosis.
Q26865956Non-invasive diagnosis of liver fibrosis in chronic hepatitis C
Q30436164Noninvasive diagnosis of cirrhosis: a review of different imaging modalities
Q88594630On Patient Related Factors and Their Impact on Ultrasound-Based Shear Wave Elastography of the Liver
Q30406316Parameters affecting different acoustic radiation force impulse applications in the diagnosis of fibrotic liver changes
Q91491597Point Shear Wave Elastography for Grading Liver Fibrosis: Can the Number of Measurements Be Reduced?
Q30439553Point shear wave elastography method for assessing liver stiffness
Q30434361Principles and clinical application of ultrasound elastography for diffuse liver disease
Q30375396Prospective Comparison of Liver Stiffness Measurements between Two Point Shear Wave Elastography Methods: Virtual Touch Quantification and Elastography Point Quantification.
Q46255835Prospective Validation of Intra- and Interobserver Reproducibility of a New Point Shear Wave Elastographic Technique for Assessing Liver Stiffness in Patients with Chronic Liver Disease
Q39605903Repeatability and Reproducibility of a Clinically Based QUS Phantom Study and Methodologies
Q48187865Repeatability and Reproducibility of the Ultrasonic Attenuation Coefficient and Backscatter Coefficient Measured in the Right Lobe of the Liver in Adults With Known or Suspected Nonalcoholic Fatty Liver Disease
Q50109194Shear wave liver elastography.
Q30432218Ultrasound in chronic liver disease
Q49501985Ultrasound or MR elastography of liver: which one shall I use?
Q90674610Validation of a New Point Shear-Wave Elastography Method for Noninvasive Assessment of Liver Fibrosis: A Prospective Multicenter Study
Q52988915Virtual Touch Tissue Imaging Quantification Shear Wave Elastography: Prospective Assessment of Cervical Lymph Nodes.
Q41392739WFUMB guidelines and recommendations for clinical use of ultrasound elastography: Part 3: liver
Q30372310What we need to know when performing and interpreting US elastography.

Search more.