The influence of different IMRT techniques on the peripheral dose: a comparison between sMLM-IMRT and helical tomotherapy.

scientific article published on 6 October 2009

The influence of different IMRT techniques on the peripheral dose: a comparison between sMLM-IMRT and helical tomotherapy. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1007/S00066-009-2005-9
P698PubMed publication ID19806336

P50authorKai SchubertQ110644099
P2093author name stringTilo Wiezorek
Andrea Schwahofer
P2860cites workAccelerated partial breast irradiation consensus statement from the American Society for Radiation Oncology (ASTRO).Q33471876
Accelerated partial breast irradiation in early-stage breast cancerQ36756968
Accelerated partial breast irradiation: consensus statement of 3 German Oncology societiesQ36890168
Multisegmented tangential breast fields: a rational way to treat breast cancerQ42696100
The effect of adjuvant radiotherapy on mortality differs according to primary tumor location in women with node-positive breast cancer.Q43532615
DEGRO practical guidelines for radiotherapy of breast cancer II. Postmastectomy radiotherapy, irradiation of regional lymphatics, and treatment of locally advanced disease.Q45909385
Accelerated partial-breast irradiation with interstitial implants. Analysis of factors affecting cosmetic outcomeQ46800099
Comparison of wedge versus segmented techniques in whole breast irradiation: effects on dose exposure outside the treatment volumeQ47658382
Evaluation of calculation algorithms implemented in different commercial planning systems on an anthropomorphic breast phantom using film dosimetry.Q50856130
Improving dose homogeneity in large breasts by IMRT: efficacy and dosimetric accuracy of different techniques.Q51893736
The Christie Hospital breast conservation trial: an update at 8 years from inceptionQ72766845
[A population-based study on variations in the use of adjuvant radiotherapy in breast cancer patients]Q78501401
Full-dose intraoperative radiotherapy with electrons in breast cancer. First report on late toxicity and cosmetic results from a single-institution experienceQ79168857
Breast-conserving treatment with partial or whole breast irradiation for low-risk invasive breast carcinoma--5-year results of a randomized trialQ80389496
Accelerated partial-breast irradiation with interstitial implants: the clinical relevance of the calculation of skin dosesQ80751706
More evidence that locoregional radiation therapy improves survival: what should we do?Q81289972
[Partial breast irradiation after breast-conserving surgery for breast cancer]Q81922249
Postoperative irradiation of left-sided breast cancer patients and cardiac toxicity. Does deep inspiration breath-hold (DIBH) technique protect the heart?Q82639836
A dosimetric comparison of IORT techniques in limited-stage breast cancerQ83351847
Wide tangential fields including the internal mammary lymph nodes in patients with left-sided breast cancer. Influence of respiratory-controlled radiotherapy (4D-CT) on cardiac exposureQ83577854
[Is cardiotoxicity still an issue after breast-conserving surgery and could it be reduced by multifield IMRT?]Q83660712
Accelerated partial breast irradiation: caution and concern from an ASTRO task forceQ84104789
P433issue10
P921main subjecthelical tomotherapyQ108575067
P304page(s)696-702
P577publication date2009-10-06
P1433published inStrahlentherapie und OnkologieQ15724604
P1476titleThe influence of different IMRT techniques on the peripheral dose: a comparison between sMLM-IMRT and helical tomotherapy.
P478volume185

Reverse relations

cites work (P2860)
Q53216879CT-myelography for high-dose irradiation of spinal and paraspinal tumors with helical tomotherapy: revival of an old tool.
Q47346625Dosimetric comparison of the helical tomotherapy, volumetric-modulated arc therapy and fixed-field intensity-modulated radiotherapy for stage IIB-IIIB non-small cell lung cancer
Q83170805Dosimetric integration of daily mega-voltage cone-beam CT for image-guided intensity-modulated radiotherapy
Q53211347Erlotinib-induced rash spares previously irradiated skin.
Q36552644High-dose pre-operative helical tomotherapy (54 Gy) for retroperitoneal liposarcoma
Q35234015In vivo measurement of dose distribution in patients' lymphocytes: helical tomotherapy versus step-and-shoot IMRT in prostate cancer
Q44129202Investigations of peripheral dose for helical tomotherapy
Q53293733New multileaf collimator with a leaf width of 5 mm improves plan quality compared to 10 mm in step-and-shoot IMRT of HNC using integrated boost procedure.
Q86482758Node-positive left-sided breast cancer: does VMAT improve treatment plan quality with respect to IMRT?
Q39266418Peripheral dose measurements with diode and thermoluminescence dosimeters for intensity modulated radiotherapy delivered with conventional and un-conventional linear accelerator
Q36736612Radiotherapy-induced malignancies: review of clinical features, pathobiology, and evolving approaches for mitigating risk
Q42660296Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy: multi-institutional planning study for head-and-neck cases
Q37719303Second malignancies in high‑dose areas of previous tumor radiotherapy
Q83674166Stereotactic body radiation therapy (SBRT) for treatment of adrenal gland metastases from non-small cell lung cancer
Q84806142Superiority of conventional intensity-modulated radiotherapy over helical tomotherapy in locally advanced non-small cell lung cancer. A comparative plan analysis
Q40953260The impact of direct aperture optimization on plan quality and efficiency in complex head and neck IMRT.
Q51573949Treatment results of radiation therapy for muscle-invasive bladder cancer.
Q87703575VMAT techniques for lymph node-positive left sided breast cancer
Q43003936Volumetric modulated arc therapy for advanced pancreatic cancer

Search more.