Optimal Contrast Application for Cardiac 4-Detector-Row Computed Tomography

scientific article published on November 1, 2003

Optimal Contrast Application for Cardiac 4-Detector-Row Computed Tomography is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1097/01.RLI.0000084886.44676.E4
P953full work available at URLhttps://journals.lww.com/10.1097/01.rli.0000084886.44676.e4
P698PubMed publication ID14566178

P50authorU Joseph SchoepfQ87903952
Maximilian ReiserQ15439977
P2093author name stringCheng Hong
Alexander Leber
Andreas Knez
Roland Bruening
Maximilian F. Reiser
Christoph R. Becker
P2860cites workCoronary angiography with multi-slice computed tomographyQ74517268
Usefulness of multislice spiral computed tomography angiography for determination of coronary artery stenosesQ77156365
Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injectionQ32165824
Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomographyQ33182060
Comparison of image quality in contrast-enhanced coronary-artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomographyQ33185806
Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstructionQ33186018
Parameters affecting bolus geometry in CTA: a reviewQ34828242
Use of high concentration contrast media: principles and rationale-vascular districtQ35070845
Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiographyQ43615498
Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Q51701061
Variation of the coronary calcium score depending on image reconstruction interval and scoring algorithm.Q52033118
Coronary artery calcium: absolute quantification in nonenhanced and contrast-enhanced multi-detector row CT studies.Q52041033
Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience.Q52071990
Evaluation of reconstruction windows for multislice computed tomography in quantification of coronary calcium.Q52947727
Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiographyQ73441854
Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thoraxQ73629404
Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injectorQ73743019
ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image qualityQ74433450
P433issue11
P407language of work or nameEnglishQ1860
P921main subjectcomputed tomographyQ32566
P304page(s)690-694
P577publication date2003-11-01
P1433published inInvestigative RadiologyQ15734073
P1476titleOptimal Contrast Application for Cardiac 4-Detector-Row Computed Tomography
P478volume38

Reverse relations

cites work (P2860)
Q87610582128-Slice dual source coronary CTA: defining optimal arterial enhancement levels
Q52945509A low-dose and an ultra-low-dose contrast agent protocol for coronary CT angiography in a clinical setting: quantitative and qualitative comparison to a standard dose protocol.
Q36691119A practical guide to reading CT coronary angiograms--how to avoid mistakes when assessing for coronary stenoses.
Q34376622ASCI 2010 contrast media guideline for cardiac imaging: a report of the Asian Society of Cardiovascular Imaging cardiac computed tomography and cardiac magnetic resonance imaging guideline working group
Q33804905Adaptive Bolus-chasing Computed Tomography Angiography in the Cases of Symmetric and Asymmetric Arterial Flows in Peripheral Arteries
Q47103295Advances in cardiac CT contrast injection and acquisition protocols
Q44796435Advances in cardiac imaging
Q33970025Biphasic contrast medium injection in cardiac CT: moderate versus high concentration contrast material at identical iodine flux and iodine dose
Q51232962Biplane interventional pediatric system with cone-beam CT: dose and image quality characterization for the default protocols.
Q47394529Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography
Q36635169Cardiac CT: coronary arteries and beyond
Q44513857Cardiac output obtained from test bolus injections as a factor in contrast injection rate revision of following coronary CT angiography
Q36829917Comparison of Iohexol-380 and Iohexol-350 for Coronary CT Angiography: A Multicenter, Randomized, Double-Blind Phase 3 Trial
Q37097207Comparison of coronary computed tomography angiography image quality with high- and low-concentration contrast agents (CONCENTRATE): study protocol for a randomized controlled trial
Q45242709Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental renal arteries
Q35647539Contrast Enhancement of the Right Ventricle during Coronary CT Angiography--Is It Necessary?
Q50620492Contrast agent bolus tracking with a fixed threshold or a manual fast start for coronary CT angiography.
Q57482343Contrast enhancement efficacy of iodinated contrast media: Effect of molecular structure on contrast enhancement
Q53199030Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography.
Q90339140Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant arti
Q58565435Development and Validation of Generalized Linear Regression Models to Predict Vessel Enhancement on Coronary CT Angiography
Q47271345Dual-source CT coronary angiography involving injection protocol with iodine load tailored to patient body weight and body mass index: estimation of optimal contrast material dose
Q36143698Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
Q85324228Enhancement of the pulmonary arteries and thoracic aorta: comparison of a biphasic contrast injection and fixed delay protocol with a monophasic injection and a timing bolus protocol
Q52984749Feasibility of 320-row area detector CT coronary angiography using 40 mL of contrast material: assessment of image quality and diagnostic accuracy.
Q43217827Feasibility of contrast material volume reduction in coronary artery imaging using 320-slice volume CT.
Q38367294Feasibility of low contrast media volume in CT angiography of the aorta
Q46105433High-pitch dual-source CT coronary angiography with low volumes of contrast medium
Q34308673Image quality and attenuation values of multidetector CT coronary angiography using high iodine-concentration contrast material: a comparison of the use of iopromide 370 and iomeprol 400.
Q83139386Influence of cardiac hemodynamic parameters on coronary artery opacification with 64-slice computed tomography
Q52879937Intra-arterial ultra low iodine CT angiography of renal transplant arteries.
Q45816238Introduction of an individually optimized protocol for the injection of contrast medium for coronary CT angiography
Q45107220Iterative image reconstruction algorithms in coronary CT angiography improve the detection of lipid-core plaque--a comparison with histology
Q50673621Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography.
Q36164837Multislice spiral computed tomography of the heart: technique, current applications, and perspective
Q45730195Novel contrast-injection protocol for coronary computed tomographic angiography: contrast-injection protocol customized according to the patient's time-attenuation response
Q58696101Personalization of injection protocols to the individual patient's blood volume and automated tube voltage selection (ATVS) in coronary CTA
Q51083735Prediction of aortic peak enhancement in monophasic contrast injection protocols at multidetector CT: phantom and patient studies.
Q31078853Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.
Q36365959Reduction of the total injection volume of contrast material with a short injection duration in 64-detector row CT coronary angiography
Q40216158Revival of monophasic contrast injection protocols: superiority of a monophasic injection protocol compared to a biphasic injection protocol in high-pitch CT angiography
Q89361864Subjective and objective image differences in pediatric computed tomography cardiac angiography using lower iodine concentration
Q37817585Technical considerations for lower limb multidetector computed tomographic angiography
Q47297570The influence of body mass index and gender on coronary arterial attenuation with fixed iodine load per body weight at dual-source CT coronary angiography
Q37697897The influence of cardiac function on coronary arterial enhancement at coronary computed tomography angiography: A cross-sectional study
Q37328016Triple rule-out CT in the emergency department: protocols and spectrum of imaging findings
Q43174196Validation of a new contrast material protocol adapted to body surface area for optimized low-dose CT coronary angiography with prospective ECG-triggering

Search more.