How to minimize failures of fixation of unstable intertrochanteric fractures

scientific article published on 01 November 1995

How to minimize failures of fixation of unstable intertrochanteric fractures is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1016/0020-1383(95)00125-S
P698PubMed publication ID8550168

P2093author name stringR Gundle
A H Simpson
M F Gargan
P433issue9
P921main subjectbone fractureQ68833
P304page(s)611-614
P577publication date1995-11-01
P1433published inInjuryQ15752765
P1476titleHow to minimize failures of fixation of unstable intertrochanteric fractures
P478volume26

Reverse relations

cites work (P2860)
Q37292772A micro-architectural evaluation of osteoporotic human femoral heads to guide implant placement in proximal femoral fractures
Q33258569A new parallel drill guide for navigating femoral neck screw placement. Development and evaluation
Q38633313A six-year retrospective analysis of cut-out risk predictors in cephalomedullary nailing for pertrochanteric fractures: Can the tip-apex distance (TAD) still be considered the best parameter?
Q51808528Biomechanical Evaluation of a New Type of Hip Compression Screw With Retractable Talons
Q42243465Biopolymer augmentation of the lag screw in the treatment of femoral neck fractures--a biomechanical in-vitro study
Q37421959Comparative prospective study of proximal femoral nail and dynamic hip screw in treatment of intertrochanteric fracture femur
Q41810167Comparison of Second and Third-Generation Nails in the Treatment of Intertrochanteric Fracture: Screws versus Helical Blades
Q50073121Evaluation of outcome of proximal femur locking compression plate (PFLCP) in unstable proximal femur fractures
Q41555090Implant failure in a proximal femoral fracture treated with dynamic hip screw fixation
Q58765290Local Postoperative Complications after Surgery for Intertrochanteric Fractures Using Cephalomedullary Nails
Q42374575Numerical Optimization of the Position in Femoral Head of Proximal Locking Screws of Proximal Femoral Nail System; Biomechanical Study
Q24241296Osteotomy, compression and other modifications of surgical techniques for internal fixation of extracapsular hip fractures
Q35574457Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures
Q36275241Reverse oblique intertrochanteric femoral fractures treated with the gamma nail
Q34337120Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients
Q91973900Scanning Electron Microscopy Study of Retrieved Implants Suggests a Ratcheting Mechanism Behind Medial Migration in Cephalomedullary Nailing of Hip Fractures
Q37589228Surgical Results of the Cephalomedullary Nail for the Femoral Intertrochanteric Fracture: Comparison between Non-experienced Surgeons and Experienced Surgeon
Q43162709Unusual mode of failure of intertrochanteric femur fracture fixation
Q79340023[Manipulation of the step borer as cause of too shallow boring depth in the femoral neck with the gamma nail system]