Definition of a moving gross target volume for stereotactic radiation therapy of stented coronary arteries

scientific article published on 01 February 2002

Definition of a moving gross target volume for stereotactic radiation therapy of stented coronary arteries is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1016/S0360-3016(01)02679-7
P698PubMed publication ID11872305

P50authorKoen NiemanQ92118088
Pim J de FeyterQ98148325
Peter NowakQ98388785
Peter C LevendagQ114402931
Stephane G CarlierQ56380798
Patrick W SerruysQ63253317
P2093author name stringEdward M Leter
Aristoteles Munne
P2860cites workLong-term clinical follow-up after successful repeat percutaneous intervention for stent restenosisQ73476791
Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosisQ73762608
Coronary angiography with multi-slice computed tomographyQ74517268
Fibrocellular tissue responses to endovascular and external beam irradiation in the porcine model of restenosisQ77811659
The effect of external electron beam on neointima in rat carotid artery injury modelQ77811664
Statistical methods for assessing agreement between two methods of clinical measurementQ26778461
Localized intracoronary gamma-radiation therapy to inhibit the recurrence of restenosis after stentingQ31921221
Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.Q33181497
Radiation injury to the heartQ40505512
Quantitative assessment of regional left ventricular motion using endocardial landmarksQ41491866
Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience.Q52071990
Endoluminal Beta-Radiation Therapy for the Prevention of Coronary Restenosis after Balloon AngioplastyQ57908164
The use of active breathing control (ABC) to reduce margin for breathing motionQ61903157
A dosimetric comparison of conventional vs conformal external beam irradiation of a stented coronary artery utilizing a new fluoroscopic imaging detector system.Q64892303
Experimental validation of geometric and densitometric coronary measurements on the new generation Cardiovascular Angiography Analysis System (CAAS II)Q72559997
Stereotactic radiotherapy of extracranial targets: CT-simulation and accuracy of treatment in the stereotactic body frameQ73131153
Cardiac motion of coronary arteries: variability in the rest period and implications for coronary MR angiographyQ73225840
Inhibition of rat smooth muscle proliferation by radiation after arterial injury: temporal characteristics in vivo and in vitroQ73341810
P433issue2
P407language of work or nameEnglishQ1860
P304page(s)560-565
P577publication date2002-02-01
P1433published inInternational Journal of Radiation Oncology Biology PhysicsQ2296252
P1476titleDefinition of a moving gross target volume for stereotactic radiation therapy of stented coronary arteries
P478volume52

Reverse relations

cites work (P2860)
Q33184015Comparison of different methods to define a target volume for external beam radiation therapy of restenotic coronary arteries.
Q33185112Dosimetric comparison between high-precision external beam radiotherapy and endovascular brachytherapy for coronary artery in-stent restenosis
Q37213202Estimation of the displacement of cardiac substructures and the motion of the coronary arteries using electrocardiographic gating.

Search more.