Comparing Entropy and the Bispectral index with the Ramsay score in sedated ICU patients

scientific article published on 16 August 2007

Comparing Entropy and the Bispectral index with the Ramsay score in sedated ICU patients is …
instance of (P31):
scholarly articleQ13442814

External links are
P6179Dimensions Publication ID1049556285
P356DOI10.1007/S10877-007-9087-7
P698PubMed publication ID17701384

P2093author name stringCarmen Hernández-Gancedo
David Pestaña
Hanna Pérez-Chrzanowska
Antonio Criado
Elena Martinez-Casanova
P2860cites workComparative evaluation of the Datex-Ohmeda S/5 Entropy Module and the Bispectral Index monitor during propofol-remifentanil anesthesiaQ28295238
Using and understanding sedation scoring systems: a systematic reviewQ30654382
Sedation for the critically ill.Q33693731
Sedation in the intensive care unitQ33884496
Bispectral analysis technology and equipmentQ34018791
Clinical practice guidelines for the sustained use of sedatives and analgesics in the critically ill adultQ34119310
Measuring the performance of anesthetic depth indicatorsQ40952096
Electromyographic activity falsely elevates the bispectral indexQ41732309
Sedative and analgesic practice in the intensive care unit: the results of a European surveyQ43700168
Bispectral index variations during tracheal suction in mechanically ventilated critically ill patients: effect of an alfentanil bolusQ43926626
Bispectral Index in ICU: correlation with Ramsay Score on assessment of sedation level.Q44290265
Overestimation of Bispectral Index in sedated intensive care unit patients revealed by administration of muscle relaxantQ44491541
Biasing effect of the electromyogram on BIS: a controlled study during high-dose fentanyl inductionQ44528708
Time-frequency balanced spectral entropy as a measure of anesthetic drug effect in central nervous system during sevoflurane, propofol, and thiopental anesthesiaQ44783340
A comparison of state and response entropy versus bispectral index values during the perioperative periodQ46861868
Monitoring sedation in critically ill patients: bispectral index, Ramsay and observer scalesQ46912961
Consciousness monitoring in ventilated patients: bispectral EEG monitors arousal not deliriumQ47985509
An assessment of the Cerebrotrac 2500 for continuous monitoring of cerebral function in the intensive care unitQ48659679
The effect of intravenous epinephrine on the bispectral index and sedation.Q51385872
What does the bispectral EEG index monitor?Q51407591
Bispectral index increases and decreases are not always signs of inadequate anesthesia.Q51411522
Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia.Q51411615
Use of continuous bispectral EEG monitoring to assess depth of sedation in ICU patients.Q51481443
Complications of sedation with midazolam in the intensive care unit and a comparison with other sedative regimens.Q51521584
A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect.Q51545956
Continuous monitoring of depth of sedation by EEG spectral analysis in patients requiring mechanical ventilation.Q51621946
Is the bispectral index appropriate for monitoring the sedation level of mechanically ventilated surgical ICU patients?Q51723056
Description of the Entropy algorithm as applied in the Datex-Ohmeda S/5 Entropy Module.Q52002363
Controlled Sedation with Alphaxalone-AlphadoloneQ55061590
Practice parameters for intravenous analgesia and sedation for adult patients in the intensive care unit: an executive summary. Society of Critical Care MedicineQ72034446
Beyond the Ramsay scale: need for a validated measure of sedating drug efficacy in the intensive care unitQ72415465
Evaluation of two processed EEG analyzers for assessment of sedation after coronary artery bypass graftingQ73697966
Validating the Sedation-Agitation Scale with the Bispectral Index and Visual Analog Scale in adult ICU patients after cardiac surgeryQ74111875
How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer studyQ74492361
Pacer-induced artifact in the bispectral index during cardiac surgeryQ78024058
Assessing sedation during intensive care unit mechanical ventilation with the Bispectral Index and the Sedation-Agitation ScaleQ78201252
Monitoring sedation in the intensive care unit: can "black boxes" help us?Q79853237
Current practices in sedation and analgesia for mechanically ventilated critically ill patients: a prospective multicenter patient-based studyQ80110273
Bispectral Index monitoring correlates with sedation scales in brain-injured patientsQ81145090
P433issue5
P304page(s)295-302
P577publication date2007-08-16
P1433published inJournal of Clinical Monitoring and ComputingQ5310493
P1476titleComparing Entropy and the Bispectral index with the Ramsay score in sedated ICU patients
P478volume21

Reverse relations

cites work (P2860)
Q42919806Comparisons of two different doses of fentanyl for procedural analgesia during epidural catheter placement: a double-blind prospective, randomized, placebo-controlled study
Q47961459Entropy correlates with Richmond Agitation Sedation Scale in mechanically ventilated critically ill patients
Q38040844Sedation for critically ill or injured adults in the intensive care unit: a shifting paradigm
Q46769326Spectral entropy as a monitor of depth of propofol induced sedation
Q42218048Spectral entropy as an objective measure of sedation state in midazolam-premedicated patients
Q35861402Spectral entropy for assessing the depth of propofol sedation
Q89767869[Application of intravenous sedation in 2 582 cases of oral and maxillofacial surgery]

Search more.