The Biomechanical Analysis of Relative Position Between Implant and Alveolar Bone: Finite Element Method

scientific article published on October 11, 2010

The Biomechanical Analysis of Relative Position Between Implant and Alveolar Bone: Finite Element Method is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1902/JOP.2010.100388
P953full work available at URLhttps://onlinelibrary.wiley.com/doi/full/10.1902/jop.2010.100388
P698PubMed publication ID20936917

P2093author name stringChau-Hsiang Wang
Huey-Er Lee
Ting-Hsun Lan
Cheng-Chun Huang
P2860cites workA conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone. An axisymmetric finite element analysisQ73584365
Crestal bone changes around titanium implants. A radiographic evaluation of unloaded nonsubmerged and submerged implants in the canine mandibleQ73960784
Biologic Width around one- and two-piece titanium implantsQ77332432
Evaluation of the effect of the residual bone angulation on implant-supported fixed prosthesis in mandibular posterior edentulism. Part II: 3-D finite element stress analysisQ77553307
The influence of non-matching implant and abutment diameters on radiographic crestal bone levels in dogsQ80637310
Evaluation of stress induced by implant type, number of splinted teeth, and variations in periodontal support in tooth-implant-supported fixed partial dentures: a non-linear finite element analysisQ82442752
Bone response to loaded implants with non-matching implant-abutment diameters in the canine mandibleQ83588921
Surgical procedures in partially edentulous patients with ITI implants.Q30327776
Influence of the size of the microgap on crestal bone changes around titanium implants. A histometric evaluation of unloaded non-submerged implants in the canine mandibleQ30666905
Peri-implant bone level around implants with platform-switched abutments: preliminary data from a prospective studyQ31116620
Loss of osseointegration caused by occlusal load of oral implants. A clinical and radiographic study in monkeysQ34413955
Dental implants in patients with bruxing habitsQ36386513
Metal-ceramic alloys in dentistry: a reviewQ37380054
Intraoral radiographic errorsQ40616328
Statistical methods in finite element analysisQ44090586
Stress analysis of different angulations of implant installation: the finite element methodQ47567541
Biomechanical response of implant systems placed in the maxillary posterior region under various conditions of angulation, bone density, and loadingQ47769648
Role of the Microgap Between Implant and Abutment: A Retrospective Histologic Evaluation in MonkeysQ47956877
Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis.Q50886165
Biomechanical analysis on platform switching: is there any biomechanical rationale?Q50962673
Peri-implant inflammation defined by the implant-abutment interface.Q51220377
Finite element analysis estimates of cement microfracture under complete veneer crownsQ72002804
Localized ridge augmentation using guided bone regeneration. 1. Surgical procedure in the maxillaQ72830436
Persistent acute inflammation at the implant-abutment interfaceQ73030344
Biological and technical complications and failures with fixed partial dentures (FPD) on implants and teeth after four to five years of functionQ73418244
P433issue3
P407language of work or nameEnglishQ1860
P921main subjectDental Stress AnalysisQ72259780
dental prosthesis designQ73348414
P304page(s)489-496
P577publication date2010-10-11
P1433published inJournal of PeriodontologyQ6295732
P1476titleThe biomechanical analysis of relative position between implant and alveolar bone: finite element method
The Biomechanical Analysis of Relative Position Between Implant and Alveolar Bone: Finite Element Method
P478volume82

Reverse relations

cites work (P2860)
Q34754784Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading
Q55419048Evaluation of the Effect of Buccolingual and Apicocoronal Positions of Dental Implants on Stress and Strain in Alveolar Bone by Finite Element Analysis.
Q58567132Finite Element Analysis and Biomechanical Testing to Analyze Fracture Displacement of Alveolar Ridge Splitting

Search more.