Dual Motor Drill Continuously Measures Drilling Energy to Calculate Bone Density and Screw Pull-out Force in Real Time

scientific article published on 25 September 2018

Dual Motor Drill Continuously Measures Drilling Energy to Calculate Bone Density and Screw Pull-out Force in Real Time is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.5435/JAAOSGLOBAL-D-18-00053
P932PMC publication ID6226295
P698PubMed publication ID30465038

P2093author name stringBrian B Gilmer
Sarah D Lang
P2860cites workEffect of fixation, soft-tissues, and scan projection on bone mineral measurements with dual energy X-ray absorptiometry (DXA).Q30667677
Taming of the Screw: A Case Report and Literature Review of Limb-Threatening Complications after Plate Osteosynthesis of a Clavicular NonunionQ35579977
Fracture fixation problems in osteoporosisQ35635051
BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.Q36666400
Uncritical use of bone mineral density in absorptiometry may lead to size-related artifacts in the identification of bone mineral determinantsQ36729415
Composite bone models in orthopaedic surgery research and education.Q38184273
Factors affecting the pullout strength of cancellous bone screwsQ38561333
A mechanical comparison of the locking compression plate (LCP) and the low contact-dynamic compression plate (DCP) in an osteoporotic bone modelQ39102111
Subclavian artery injury caused by a screw in a clavicular compression plateQ39429013
False aneurysm of the profunda femoris artery following internal fixation of an intertrochanteric femoral fractureQ40119907
A meta-analysis of previous fracture and subsequent fracture riskQ40494142
Hip fractures in the elderly: a world-wide projectionQ41104614
Inadvertent screw stripping during ankle fracture fixation in elderly boneQ41137566
Salvaging the pullout strength of stripped screws in osteoporotic boneQ41858033
A comparison of screw insertion torque and pullout strengthQ43805777
Optimizing bone screw pullout forceQ44568006
In situ femoral dual-energy X-ray absorptiometry related to ash weight, bone size and density, and its relationship with mechanical failure loads of the proximal femurQ47232873
Cyclic loading of periprosthetic fracture fixation constructsQ47716425
How many women have osteoporosis? JBMR Anniversary Classic. JBMR, Volume 7, Number 9, 1992.Q48627029
Direct clinical and welfare costs of osteoporotic fractures in elderly men and women.Q50613511
Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength.Q51014841
Comparison of lateral locking plate and antiglide plate for fixation of distal fibular fractures in osteoporotic bone: a biomechanical study.Q51130147
Effects of surgical errors on small fragment screw fixation.Q51167461
Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine.Q51639319
Popliteal aneurysm after plate osteosynthesis: A case reportQ58297315
Impact of soft tissue on in vivo accuracy of bone mineral measurements in the spine, hip, and forearm: a human cadaver studyQ71773677
Strength of anterior vertebral screw fixation in relationship to bone mineral densityQ71860959
Vertebral fractures predict subsequent fracturesQ73092911
Evaluation of bone strength: correlation between measurements of bone mineral density and drilling forceQ74343544
Vascular injuries complicating osteosynthesis in proximal femur fracturesQ77413100
Increased pedicle screw pullout strength with vertebroplasty augmentation in osteoporotic spinesQ78046976
Drilling, not a benign procedure: laboratory simulation of true drilling depthQ83003965
Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radiusQ83468748
Biomechanical analysis of bone mineral density, insertion technique, screw torque, and holding strength of anterior cervical plate screwsQ89563558
P433issue9
P304page(s)e053
P577publication date2018-09-25
P1433published inJAAOS: Global Research & ReviewsQ73378975
P1476titleDual Motor Drill Continuously Measures Drilling Energy to Calculate Bone Density and Screw Pull-out Force in Real Time
P478volume2

Reverse relations

Q89698139A New Site Preparation Protocol That Supports Bone Quality Evaluation and Provides Predictable Implant Insertion Torquecites workP2860

Search more.