A novel microfluidic microelectrode chip for a significantly enhanced monitoring of NPY-receptor activation in live mode.

scientific article published on 9 November 2017

A novel microfluidic microelectrode chip for a significantly enhanced monitoring of NPY-receptor activation in live mode. is …
instance of (P31):
scholarly articleQ13442814

External links are
P356DOI10.1039/C7LC00754J
P698PubMed publication ID29119176

P50authorAnnette Gabriele Beck-SickingerQ6451282
Detlev BelderQ42685161
Andrea A RobitzkiQ106851683
P2093author name stringBernd Abel
Heinz-Georg Jahnke
Franziska D Zitzmann
Felix Nitschke
P2860cites workGet to Understand More from Single-Cells: Current Studies of Microfluidic-Based Techniques for Single-Cell AnalysisQ26799356
Fluid shear stress activates YAP1 to promote cancer cell motilityQ30835797
Hydrodynamic damage to animal cells.Q34307322
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devicesQ34432966
Label-free whole-cell assays: expanding the scope of GPCR screeningQ37769932
Dielectric spectroscopy as a viable biosensing tool for cell and tissue characterization and analysisQ38116658
Accessing new chemical entities through microfluidic systemsQ38209736
A review of impedance measurements of whole cellsQ38619203
Bioprinting and Organ-on-Chip Applications Towards Personalized Medicine for Bone Diseases.Q38673908
Multiplexed Point-of-Care Testing - xPOCT.Q38689425
Impedimetric real-time monitoring of neural pluripotent stem cell differentiation process on microelectrode arraysQ38759379
Changes of cell electrical parameters induced by electroporation. A dielectrophoresis studyQ39274032
Tumour-on-a-chip: microfluidic models of tumour morphology, growth and microenvironment.Q39388967
An impedimetric microelectrode-based array sensor for label-free detection of tau hyperphosphorylation in human cellsQ39856242
Microelectrode chip based real time monitoring of vital MCF-7 mamma carcinoma cells by impedance spectroscopyQ39983848
A review of the effects of shear and interfacial phenomena on cell viabilityQ40813831
Monitoring impedance changes associated with motility and mitosis of a single cellQ42670403
Shear stress-induced endothelial cell polarization is mediated by Rho and Rac but not Cdc42 or PI 3-kinasesQ42917027
Effect of shear stress on migration and integrin expression in macaque trophoblast cellsQ44006946
Hybrid polymer microfluidic platform to mimic varying vascular compliance and topologyQ47982638
On-chip integration of organic synthesis and HPLC/MS analysis for monitoring stereoselective transformations at the micro-scale.Q48192297
Enantioselective reaction monitoring utilizing two-dimensional heart-cut liquid chromatography on an integrated microfluidic chipQ48238021
Quantitative characterization of capsaicin-induced TRPV1 ion channel activation in HEK293 cells by impedance spectroscopy.Q50227464
A cell-based impedance assay for monitoring transient receptor potential (TRP) ion channel activity.Q50555975
Responses of human adipose-derived stem cells to interstitial level of extremely low shear flows regarding differentiation, morphology, and proliferation.Q50863924
A droplet-chip/mass spectrometry approach to study organic synthesis at nanoliter scale.Q50871545
nDEP microwells for single-cell patterning in physiological media.Q50929698
Comparison of Chip Inlet Geometry in Microfluidic Devices for Cell Studies.Q51287608
Chip-based electrochromatography coupled to ESI-MS detection.Q51469439
On-chip monitoring of chemical syntheses in microdroplets via surface-enhanced Raman spectroscopy.Q51500843
Towards an integrated device that utilizes adherent cells in a micro-free-flow electrophoresis chip to achieve separation and biosensing.Q51532119
Multistep liquid-phase lithography for fast prototyping of microfluidic free-flow-electrophoresis chips.Q51546131
Conductivity values of tissue culture medium from 20 degrees C to 40 degrees C.Q52652391
Quantitative impedimetric NPY-receptor activation monitoring and signal pathway profiling in living cells.Q53018278
P433issue24
P921main subjectmicrofluidicsQ138845
P1104number of pages9
P304page(s)4294-4302
P577publication date2017-11-09
P1433published inLab on a ChipQ3214277
P1476titleA novel microfluidic microelectrode chip for a significantly enhanced monitoring of NPY-receptor activation in live mode.
P478volume17

Reverse relations

Q91781214High-Density Electrical Recording and Impedance Imaging With a Multi-Modal CMOS Multi-Electrode Array Chipcites workP2860

Search more.